Lowara 10HM04N15T Stainless Steel Steady Multistage Centrifugal Pump for Utility Water with Closed Impeller
SKU: 10HM04N15T

Lowara 10HM04N15T Stainless Steel Steady Multistage Centrifugal Pump for Utility Water with Closed Impeller

$1,804.72 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
233 L/Min
Max Head
44.8 m
Power
1.5 kW / 415v
Ideal Use
Process water and HVAC circulation.

Product Overview

High-volume HVAC circulation systems and demanding commercial water treatment networks rely on structured centrifugal force generation. Facilities deploy the Lowara 10HM04N15T stainless steel multistage pump to support utility operations and establish stable temperature control processing.

Pumping capacities deliver a Max Head 44.8 m while sustaining a steady Max Flow 233 L/Min. The drive unit consumes 1.5 kW of energy running exclusively via a 415v three-phase electrical circuit. System connections dictate exactly 40 mm fittings for the suction and 32 mm for the discharge.

Fluid dynamic stability is achieved through a carefully aligned multistage arrangement. This non-self-priming centrifugal mechanism securely directs liquid mechanically from the axial inlet toward the radial outlet, optimizing circulation pressure and limiting mechanical turbulence.

The fully metallic AISI 316 stainless steel construction protects vital wetted components from operational wear. External defense is provided by a short-circuit squirrel-cage motor carrying an IP 55 environmental rating, combined with a precise mechanical seal.

FEATURES
  • Wetted parts constructed entirely from AISI 316 stainless steel
  • Horizontal mechanical mounting configuration
  • Air-cooled TEFC continuous duty electric surface motor
  • Approved for safe drinking water usage (WRAS and ACS)
  • Thermal electrical insulation system strictly rated to Class 155 (F)
  • Precise O-ring mechanical seal preventing fluid displacement
  • Operates safely with fluids ranging from -10°C to +120°C
SPECIFICATIONS
Max Flow233 L/Min
Max Head44.8 m
Power1.5 kW / 415v
Rated Current3.12 Amps
Suitable ForProcess water and HVAC circulation.
Body MaterialAISI 316 Stainless Steel
Liquid Temperature-10°C to +120°C
Inlet Size40 mm
Outlet Size32mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

HVAC circulation and water-treatment systems benefit from consistent movement when clean liquid must pass through larger service networks. The Lowara 10HM04N15T suits temperature-control, utility-water and continuous circulation applications.

  • HVAC Circulation
  • Water Treatment
  • Temperature Control
  • Utility Water

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
What motor kilowatt rating and electrical supply voltage current characteristics operate this unit?

Driven by a 1.5 kW (2.0 HP) electric motor, the 10HM04N15T requires 380–415 V, 50 Hz, three-phase at a current draw of 5.40 / 3.12 A.

What liquid temperature tolerances and maximum working pressure boundaries are certified for this pump?

High pressure tolerance on the 10HM-04N-15T is certified for a maximum working pressure rating of 16 bar (PN 16) with fluid temperature capabilities from -10°C to +120°C.

What peak vertical head elevation can this clean water supply unit generate upward?

Upward vertical push reaches a maximum dynamic elevation head of approximately 44.8 m on the 10HM 04N 15T.

At full capacity, what maximum water flow rate and connection port diameter are output?

Water circulation volume peaks at a delivery flow rate of approximately 233 L/Min on the 10HM_04N_15T, utilizing Rp 1-1/2" (40 mm) suction and Rp 1-1/4" (32 mm) discharge.

Across wet internal surfaces, what alloy composition and seal construction prevent fluid corrosion?

Corrosion resilience across the 10HM04N15T is ensured by AISI 316L stainless steel pump casing, diffusers, and closed impellers alongside precision mechanical face seals.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed