Product Overview
Designed for demanding industrial environments, this three-phase twin-impeller pump serves critical applications ranging from high-precision industrial washing to reverse osmosis water circulation. Its construction in AISI 316L stainless steel makes it the preferred choice for handling chemically sensitive fluids and thermally active water in agricultural, civil, and specialized industrial sectors.
The unit provides substantial hydraulic performance, delivering flow rates reaching approximately 150 L/Min. It supports high-pressure requirements with a maximum head capacity of approximately 59.6 metres, ensuring consistent pressure for sustained circulation duties in professional processing plants.
Engineered with a high-performance enclosed twin-impeller design, the pump minimizes hydraulic turbulence and optimizes energy efficiency. The close-coupled motor configuration, paired with a reliable FPM mechanical seal, offers chemical resistance and longevity in aggressive liquid transfer applications.
Installation is simplified through standard threaded suction and discharge ports, featuring a 32mm inlet and a 25mm outlet. The motor is encased in an IP55-rated housing with external ventilation to ensure stable operation. Thermal overload protection must be provided by the user within the facility's control panel.
Features:
- Constructed with AISI 316L stainless steel for maximum corrosion resistance
- FPM elastomer seals provided as standard for fluid compatibility
- Close-coupled design for compact mounting on industrial skids
- Asynchronous squirrel cage motor with IP55 protection rating
- Threaded ISO 7 port connections for standard plumbing integration
- Suitable for continuous duty in specialized liquid handling systems
SPECIFICATIONS
| Max Flow | 150 L/Min |
| Max Head | 59.6 m |
| Power | 2.2 kW / 415v |
| Rated Current | 4.65 Amps |
| Suitable For | Industrial Washing and Thermal Water Handling |
| Body Material | AISI 316L Stainless Steel |
| Liquid Temperature | -10°C to +110°C |
| Inlet Size | 32 mm |
| Outlet Size | 25 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What three-phase supply voltage and electrical power input are specified for this heavy process pump?
Electrical parameters for running the CA120/55N-V specify a 2.2 kW drive on 380–415 V, 50 Hz, three-phase with a nominal current of 4.65 A and IP55 dust and water spray protection, Class F insulation.
Where should this heavy twin-impeller process pump be sited to ensure proper drainage and stability?
Vibration-free operation is maintained by securing the CA120-55N-V to a solid horizontal floor with an integrated foundation and proper drainage.
What maximum dynamic elevation head does this heavy twin-impeller process pump reach?
Twin-stage hydraulic impellers allow the CA 120 55N V to reach a maximum dynamic elevation head of approximately 63.8 m.
What peak water flow volume does this twin-impeller process pump deliver through its discharge port?
Fluid delivery across commercial supply circuits is maintained by the CA_120_55N_V, discharging a maximum flow volume of approximately 180 L/Min via Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge ports.
What construction materials and specialized mechanical seal elastomers protect this process pump?
Superior metallurgical endurance against fluid corrosion relies on alloy materials in the CA120/55N-V, featuring AISI 316L stainless steel casing and dual impellers, with specialized FPM (Viton) elastomers, accommodating temperatures from -10°C to +110°C.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us