Lowara COM 350/15 Stainless Steel High-Flow Centrifugal Pump for Cooling Systems with Open Impeller
SKU: COM350/15

Lowara COM 350/15 Stainless Steel High-Flow Centrifugal Pump for Cooling Systems with Open Impeller

$2,800.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
500 L/Min
Max Head
16.9 m
Power
1.91 kW / 240v
Ideal Use
Industrial Washing and Cooling Systems

Product Overview

The Lowara COM 350/15 is engineered for professionals requiring reliable liquid movement in civil and industrial environments. This unit serves as an ideal solution for applications where process water handling, cooling system circulation, or transfer of clean liquids containing suspended solids is critical. By utilizing a durable, single-impeller design, it consistently solves flow challenges in tight or demanding operational spaces.

Built for performance, this pump features a maximum capacity of Max Head 16.9 m and Max Flow 500 L/Min. With a total power rating of 1.91 kW / 240v, the COM 350/15 integrates a high-efficiency TEFC motor. The unit is optimized for plumbing systems with an inlet size of 40 mm and an outlet size of 32 mm, ensuring seamless connectivity for standard infrastructure requirements and reliable fluid delivery.

Construction excellence defines the CO series, which employs AISI 316L stainless steel across the pump body, seal housing disk, and open impeller to resist corrosion in chemical or industrial applications. The asynchronous squirrel cage motor operates with continuous duty, supported by an external ventilation system. FKM elastomers are standard, ensuring chemical resistance and stability across a wide temperature range of -10°C to +110°C.

Installation is simplified through a robust design featuring a galvanized steel support foot for vibration reduction and a compact 23 kg footprint. Safety is integral to the single-phase motor, which includes built-in automatic reset thermal overload protection. The unit is IP55 rated, providing protection against dust and low-pressure water jets, making it suitable for both indoor machinery installations and sheltered outdoor liquid transfer stations.

Features:

  • AISI 316L stainless steel construction for maximum corrosion resistance
  • FKM elastomers suitable for temperatures from -10°C up to 110°C
  • IP55 rated TEFC asynchronous motor with external ventilation cooling
  • Integrated automatic reset thermal overload protection for single-phase safety
  • Galvanized steel support base designed for reduced installation vibration
  • Hydraulic performance testing certified compliant with ISO 9906:2012 standards
SPECIFICATIONS
Max Flow500 L/Min
Max Head16.9 m
Power1.91 kW / 240v
Rated Current8.65 Amps
Suitable ForIndustrial Washing and Cooling Systems
Body MaterialAISI 316L Stainless Steel
Liquid Temperature-10°C to +110°C
Inlet Size40 mm
Outlet Size32 mm
Warranty12 Months
Documents
Specification Datasheet Download
Operating Manual Download

For cooling circuits and equipment-washing duties involving process water, the Lowara COM 350/15 offers dependable circulation. Its open-impeller design is suited to liquid-handling applications where minor suspended content can be encountered during routine operation.

  • Cooling Systems
  • Process Water
  • Parts Washing
  • Water Re-circulation

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Operating Manual
Download
What construction alloys and mechanical seals protect this open-impeller pump from chemical corrosion?

Corrosion resistance in demanding slurry and parts washing tasks relies on alloy metallurgy materials in the COM350/15, featuring AISI 316L stainless steel casing and open impeller, with ceramic/carbon/FPM mechanical seal accommodating suspended solids up to 11 mm in diameter.

What electrical power input and single-phase supply voltage are required for this industrial cooling pump?

Operating the motor on the COM350-15 requires a 1.5 kW electrical feed on 220–240 V, 50 Hz, single-phase drawing 9.21 A, built with IP55 dust and water spray protection, Class F insulation.

What horizontal mounting orientation is recommended for this open-impeller industrial cooling pump?

Positioning on a rigid horizontal surface in sheltered plant areas protects the COM 350 15 while maintaining an integrated base and adequate floor drainage.

What peak dynamic head is generated by this open-impeller industrial cooling pump?

Hydraulic pressure elevation in food and beverage washing is driven by the COM_350_15, yielding a maximum dynamic head of approximately 20.3 m.

What delivery flow volume is produced by this open-impeller industrial cooling pump through its outlet?

Process liquid delivery is maintained by the COM350/15, discharging a peak flow volume of approximately 500 L/Min through its Rp 1-1/2" (40 mm) suction and Rp 1-1/4" (32 mm) discharge ports.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed