Roll over image to zoom
SKU: NSCS40-200/55
Lowara NSCS40 200/55 Stainless Steel End Suction Centrifugal Pump for HVAC Management with Closed Impeller
Australia-Wide
(08) 9240 2992
Official Lowara
Peace of Mind
Product Overview
Designed to excel in demanding water treatment applications, the Lowara NSCS40-200/55 ensures reliable liquid handling across complex municipal and commercial filtration networks. Its robust architectural framework supports continuous duty service in environments requiring highly stable fluid movement without interruption.
Drawing electrical power from a continuous-duty 5.5 kW / 415v three-phase motor, this system pushes a maximum flow of approximately 672 L/Min and achieves a maximum head of approximately 36.6 m. System integration utilizes standardized metric commercial plumbing, relying on a 65 mm suction port alongside a 40 mm discharge outlet.
Internal fluid dynamics are expertly managed through a precision-crafted centrifugal passageway that prioritizes volumetric consistency. The dynamically balanced closed impeller configuration actively combats destructive internal turbulence, ensuring the unit maintains its output characteristics uniformly across heavy operational loads.
Mechanically secured with a highly rigid stub shaft mounting arrangement, the framework pairs a tough Cast Iron outer casing with a Fabricated Stainless Steel (AISI 316) impeller. With its IP55 motor protection class and an industrial-grade sealing arrangement, it safely handles extreme liquid temperatures ranging up to +120 °C.
FEATURES
- Heavy-duty rigid stub shaft alignment
- Premium Cast Iron external structural housing
- Fabricated AISI 316 Stainless Steel impeller
- Continuous duty three-phase standard motor
- IP55 environmental moisture and dust protection
- Safe operational handling of liquids up to +120 °C
- Simplified back pull-out service access configuration
SPECIFICATIONS
| Max Flow | 672 L/Min |
| Max Head | 36.6 m |
| Power | 5.5 kW / 415v |
| Rated Current | 10.7 Amps |
| Suitable For | HVAC and Industrial Water Circulation |
| Body Material | AISI 316 Stainless Steel |
| Liquid Temperature | -25°C to +120°C |
| Inlet Size | 65 mm |
| Outlet Size | 40 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
When pushing liquid upward, what dynamic head elevation does this flanged end-suction centrifugal pump develop?
Lifting in multi-story elevation loops, the NSCS40-200/55 produces a maximum dynamic head of approximately 36.6 m to lift fluid upward.
Across piping circuits, what delivery flow volume and connection port diameters are sustained by this flanged end-suction centrifugal pump?
Outputting into building service circuits, the NSCS40-200-55 delivers a peak delivery flow rate of approximately 672 L/Min discharging through DN 65 suction and DN 40 discharge flanged ports.
To resist corrosive fluid degradation, what alloy metallurgy and mechanical seals are built into this flanged end-suction centrifugal pump?
Machined against fluid chemical attack, the NSCS40 200 55 features alloy construction of cast iron casing with stainless steel closed impellers with mechanical face seals to resist corrosion and chemical attack.
What electrical motor rating in kilowatts and supply voltage current draw are featured on this flanged end-suction centrifugal pump?
Operated under nominal voltage supply, the NSCS40_200_55 is powered by an electric motor rated at 5.5 kW (7.5 HP) running on 380–415 V, 50 Hz, three-phase with a current draw of 10.5 / 6.05 A.
How much working pressure in bar and what allowable liquid temperature limits are supported here on this flanged end-suction centrifugal pump?
Sustaining within approved operating limits, the NSCS40-200/55 sustains a maximum working pressure capability of 16 bar (PN 16) across liquid operating temperatures from -25°C to +120°C.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us