Lowara NSCS50 200/110 Stainless Steel Single Stage Centrifugal Pump for Commercial Layouts with Closed Impeller
SKU: NSCS50-200/110

Lowara NSCS50 200/110 Stainless Steel Single Stage Centrifugal Pump for Commercial Layouts with Closed Impeller

$8,348.51 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
1326 L/Min
Max Head
43.5 m
Power
11 kW / 415v
Ideal Use
Water Distribution

Product Overview

Large-scale utility networks rely on stable pressure regulation to distribute water across expansive infrastructure. The Lowara NSCS50-200/110 high-capacity centrifugal unit acts as a mechanical driver for industrial water boosting, providing steady fluid delivery for commercial layouts.

Delivery output features a maximum head rating of approximately 43.5 m and a volume output reaching 1326 L/Min. Powered by a 415v three-phase electrical framework, the 11.0 kW motor registers 19.2 Amps during standard operation. Plumbing connectivity utilizes a 65 mm suction flange paired with a 50 mm discharge flange.

The internal pathways are shaped to restrict intake cavitation and promote smooth pressurized distribution. By managing directional water momentum, the pump produces a predictable flow velocity that supports industrial layouts without experiencing disruptive energy losses.

Constructed from fabricated AISI 316 stainless steel, the wetted elements tolerate operational fluid temperatures ranging between -25°C and +120°C. The exterior incorporates thermal insulation materials and structural bracing to maintain electrical safety over extended continuous lifespans.

FEATURES

  • Close-coupled motor adapter bracket removes the need for complex field alignment procedures during installation
  • Innovative back pull-out assembly isolates the rotating elements for rapid technical inspection
  • Thickened volute geometry safely absorbs the hydraulic shock common in centralized plumbing grids
  • Industrial-grade insulation protects the internal stator windings against operational heat generation
  • Interchangeable mechanical seal arrangement accommodates varied industrial fluids for widespread facility versatility
  • Galvanized carbon steel hardware fastens the primary casing structure to prevent mechanical shifting
  • Cast iron drive bracket supplies structural rigidity for the attached high-voltage assembly
SPECIFICATIONS
Max Flow1326 L/Min
Max Head43.5 m
Power11 kW / 415v
Rated Current19.2 Amps
Suitable ForWater Distribution
Body MaterialAISI 316 Stainless Steel
Liquid Temperature-25°C to +120°C
Inlet Size65 mm
Outlet Size50 mm
Warranty12 Months
Documents
Specification Datasheet Download
Quick Startup Guide Download
Operating Manual Download

Large utility networks require dependable pressure support when water must travel through extended distribution systems. The Lowara NSCS50-200/110 is suited to water boosting, central distribution and facility supply arrangements serving multiple downstream zones.

  • Water Boosting
  • Central Supply
  • Extended Pipe Runs
  • Zone Supply

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Quick Startup Guide
Download
Operating Manual
Download
Which motor power kilowatt rating and electrical supply voltage feed are certified for this flanged end-suction centrifugal pump?

Actuated by commercial electrical feeds, the NSCS50-200/110 relies on an electric motor rated at 11 kW (15.0 HP) energized via 380–415 V, 50 Hz, three-phase drawing 19.2 A.

What maximum working pressure capability and permissible fluid temperature range protect this flanged end-suction centrifugal pump?

Configured under certified hydraulic pressure, the NSCS50-200-110 sustains a maximum working pressure boundary of 16 bar (PN 16) and operating temperatures from -25°C to +120°C.

What vertical push and dynamic elevation head are developed by this flanged end-suction centrifugal pump?

Generating across vertical pipe runs, the NSCS50 200 110 reaches a maximum dynamic elevation head of approximately 43.5 m across vertical runs.

For downstream piping runs, what peak flow volume and discharge connection diameters apply to this flanged end-suction centrifugal pump?

Piping across connected plumbing lines, the NSCS50_200_110 delivers a peak volumetric flow of approximately 1326 L/Min via connected DN 65 suction and DN 50 discharge flanged ports.

How does the alloy metallurgy and mechanical seal design provide corrosion resilience in this flanged end-suction centrifugal pump?

Produced with alloy metallurgy components, the NSCS50-200/110 employs alloy construction of cast iron casing with stainless steel closed impellers with mechanical face seals to guard against chemical attack and corrosion.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed