Lowara 1HM07S05T Stainless Steel Resilient Multistage Centrifugal Pump for Light Cooling with Closed Impeller
SKU: 1HM07S05T

Lowara 1HM07S05T Stainless Steel Resilient Multistage Centrifugal Pump for Light Cooling with Closed Impeller

$1,145.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
40 L/Min
Max Head
41.9 m
Power
0.55 kW / 415v
Ideal Use
Industrial and Commercial Clean Liquid Transfer

Product Overview

Fluid transfer in specialized process circulation loops benefits from the resilient architecture of the Lowara 1HM07S05T. This horizontal multistage assembly handles clean liquids in systems ranging from light industrial cooling to domestic pressure boosting. By employing a close-coupled configuration, the unit minimizes footprint requirements in confined plant rooms or wall-mounted equipment skids.

Operational threshold limits are defined by a Max Head 41.9 m alongside a Max Flow 40 L/Min. The motor consumes 0.55 kW / 415v during active cycles. Hydraulic performance remains consistent across extended duty cycles, with the pump achieving an electrical draw of 1.29 Amps under load.

Kinetic energy conversion relies on a multistage arrangement featuring AISI 304 stainless steel vanes. These components are secured within the casing to maintain high-pressure stability during rapid fluid acceleration. The internal geometry is calibrated to reduce turbulence while ensuring the pump manages variable load conditions within the -10°C to +120°C temperature range.

External protection consists of a fully treated stainless steel shell with an IPX5 rating for the pump body. The motor utilizes a TEFC design for heat dissipation during continuous operation. Plumbing integration is facilitated by standard 25mm suction and delivery ports, providing a secure, leak-resistant connection to existing piping infrastructure.

Features:

  • TEFC 2-pole squirrel-cage motor configuration for consistent duty
  • Standardized 25mm suction and delivery thread dimensions
  • ISO 9906:2012 Grade 3B hydraulic compliance verification
  • Silicon carbide and EPDM mechanical seal interface components
  • Certified for potable water distribution and processing
  • Operating weight mass of 10 kg for installation versatility
SPECIFICATIONS
Max Flow40 L/Min
Max Head41.9 m
Power0.55 kW / 415v
Rated Current1.29 Amps
Suitable ForIndustrial and Commercial Clean Liquid Transfer
Body MaterialAISI 304 Stainless Steel
Liquid Temperature-10°C to +120°C
Inlet Size25 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

Domestic pressure boosting and cooling circuits can benefit from the steady clean-liquid delivery of the Lowara 1HM07S05T. It also fits specialised process circulation systems where compact pumping equipment must support reliable water movement within limited installation space.

  • Domestic Supply
  • Pressure Boosting
  • Cooling Systems
  • Process Circulation

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
What peak dynamic head elevation is delivered by this high-pressure multistage unit?

Vertical discharge pressure from the 1HM07S05T provides a maximum dynamic lift head of approximately 42.4 m.

What peak fluid delivery volume is discharged through the outlet port of this booster?

Piping networks interface directly with the 1HM-07S-05T across Rp 1" (25 mm) suction and Rp 1" (25 mm) discharge, accommodating a maximum delivery flow rate of approximately 40 L/Min.

How does the stainless alloy construction safeguard this high-stage pump against fluid corrosion?

Corrosion resistance on the 1HM 07S 05T is achieved through an all-stainless AISI 304 casing and closed impeller metallurgical construction.

What supply voltage and motor power rating in kilowatt are required for this three-phase pump?

Electrical power delivery for the 1HM_07S_05T utilizes a 380–415 V, 50 Hz, three-phase connection, energizing the 0.55 kW (0.75 HP) motor power at an electrical current of 1.29 A.

What horizontal mounting orientation and non-return check valve setup apply to this three-phase unit?

Ensuring proper floor drainage, the 1HM07S05T must be mounted on a horizontal base, while an external in-line check valve eliminates reverse flow.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed