Grundfos MAGNA3 40-120-F Cast Iron Single Phase Circulator Pump with Composite Impeller
SKU: 97924270

Grundfos MAGNA3 40-120-F Cast Iron Single Phase Circulator Pump with Composite Impeller

$3,750.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
235.7 L/Min
Max Head
12 m
Power
0.43 kW / 240v
Ideal Use
High Flow Chilled Water Circulation

Product Overview

For HVAC water circulation and climate control circuits, the Grundfos MAGNA3 40 120 F canned-rotor unit utilizes a glandless pump design with DIN DN 40 connection ports. The integrated control box manages operational settings without external shaft seals. Fluid circulation serves commercial heating loops, chilled water networks, and ground-source heat pump exchangers.

Hydraulic performance delivers a maximum head of 12.0 meters and a maximum flow rate of 235.7 L/Min, matching 14.14 m3/h. Powered by a permanent-magnet motor, the unit operates on a 240 V single-phase supply at 50/60 Hz, with power input P1 of 427 W and current draw of 1.96 Amps. Maximum system operating pressure is rated at 10 bar.

Housing construction features a cast iron casing grade EN 1561 EN-GJL-200 enclosing a composite impeller. Internal components incorporate a carbon-fibre rotor can, stainless steel rotor cladding, and bearing plate, running on ceramic bearings. Net weight is 16 kg with a 250 mm port length, handling liquid temperatures -10 to 110 °C.

Control features include AUTOADAPT and FLOWADAPT operating modes with integrated differential pressure and temperature sensors. Wireless communication connects via Bluetooth to Grundfos GO Remote software for diagnostics. External interfaces provide two digital inputs, two signal relays, and a 0-10V analog input.

Features

  • Energy Efficiency Index (EEI): 0.18 meeting European Union energy performance standards.
  • Maximum rotational speed rating: 4080 rpm for continuous hydraulic balancing across system curves.
  • Physical shipping package volume and gross weight: 0.039 m3, 17.5 kg for logistics planning.
  • Standard regulatory compliance approvals: CE,VDE,EAC,MOROCCO,UKC for international building code conformity.
  • Enclosure protection rating: IPX4D moisture resistance rating for commercial equipment rooms.
  • Intelligent control regulation: AUTOADAPT, FLOWADAPT, and active FLOWLIMIT operational modes.
  • Wireless connectivity: Integrated Bluetooth interface for Grundfos GO Remote application access.
  • Casing thermal insulation: Includes clip-on shell insulation covers for system heat retention.
SPECIFICATIONS
Max Flow235.7 L/Min
Max Head12 m
Power0.43 kW / 240v
Rated Current1.96 Amps
Suitable ForHigh Flow Chilled Water Circulation
Body MaterialCast Iron
Liquid Temperature'-10°C to +110°C
Inlet Size40 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Quick Guide Download

Air handling unit heating coils and central chiller secondary loops deploy the Grundfos MAGNA3 40-120-F for variable-flow fluid circulation. Differential pressure sensor feedback enables exact proportional control, maintaining constant coil discharge air temperatures.

  • Air Handling Units
  • Chiller Secondary Loops
  • Heating Coils
  • HVAC Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Quick Guide
Download
How does the metallurgical casing design defend this commercial pump against particulate wear?

Manufacturing standards for the MAGNA3 40-120-F specify a Cast Iron housing with composite impeller providing exceptional defense against thermal stresses.

What supply voltage and motor power kilowatt rating are designated for this cast iron unit?

Functioning on building electrical distribution, the Grundfos MAGNA3 40-120-F employs a motor rated at 0.43 kW (430 W) running on 240 V drawing a rated current of 1.96 Amps.

How much system operating pressure in bar and liquid temperature can this circulator sustain?

Chilled and hot water guidelines establish that the MAGNA3-40-120-F sustains system pressures up to 10 bar across liquid temperatures from -10°C to +110°C.

Under peak operation, what dynamic head and fluid lift elevation does this circulator develop?

Elevating hydronic fluid through circulation loops, the Grundfos MAGNA3 40 120 F reaches a peak dynamic head rating of approximately 12 m.

What delivery flow rate and connection flange diameter are engineered into this heating unit?

Supplying multi-zone hydronic loops, the MAGNA3_40_120_F maintains a maximum delivery flow rate of approximately 235.7 L/Min through DN 40 flanged connections.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed