Grundfos SLV.80.100.11.4.50B.C Cast Iron 4-Pole Submersible Pump for Sewage Handling with SuperVortex Impeller
SKU: 98626017

Grundfos SLV.80.100.11.4.50B.C Cast Iron 4-Pole Submersible Pump for Sewage Handling with SuperVortex Impeller

$5,952.21 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
984 L/Min
Max Head
7.2 m
Power
1.1 kW / 415v
Ideal Use
Volumetric Raw Sewage

Product Overview

Highlighting a profoundly resilient material foundation, the SLV.80.100.11.4.50B.C incorporates a spectacularly dense EN-GJL-250 cast iron exterior architecture. Designed explicitly as a rugged non-self-priming, single-stage, centrifugal pump designed for handling wastewater, process water and unscreened raw sewage, this specific machine flawlessly tackles rigorous environmental conditions.

The precisely manufactured dimensional layout is specifically optimized to effortlessly facilitate dense raw material transfers. Thick unscreened waste liquids are drawn powerfully through an 80 millimeter flanged suction inlet and immediately ejected out of a substantially wider 100 millimeter discharge port, actively averting structural clogs and catastrophic system bottlenecks.

Generating absolute physical authority over severe submerged liquid volumes, the sophisticated motor heavily relies on a balanced 3-phase 415v electrical supply matrix. Needing only a 1.1 kW power input while carefully drawing 2.9 Amps during continuous runtime, the rotational assembly produces an approximate maximum flow output measuring precisely 984 L/Min confidently.

Guaranteeing unyielding fluid optimization across challenging subterranean operations, the reinforced structure forces heavy suspended liquids vertically to achieve an approximate maximum head of 7.2 meters. With integrated embedded thermal controls continuously monitoring the winding matrix, the apparatus flawlessly avoids destructive temperature spikes to prolong the operational lifecycle.

Features

  • Engineered around a high-capacity SuperVortex impeller to safely allow passage of raw debris and solids up to 80 millimeters.
  • Uses an exclusive stainless-steel clamp assembling system ensuring fast and effortless pump housing separation for service.
  • Utilizes a high-grade dual silicon carbide primary shaft seal configuration (SIC/SIC) to entirely eliminate internal chamber leaks.
  • Includes dedicated internal moisture sensor arrays for accurate early-warning monitoring of submerged structural casing conditions.
  • Provides top-tier ingress defense through an IP68 enclosure class rating accompanied by an H level thermal insulation rating.
  • Calibrated to spin steadily at 1452 rpm, effectively balancing intense raw flow capacity with long-term mechanical longevity.
  • Fitted securely with an extended 10 meter heavy-duty 07RN8-F cable jacket engineered for challenging deep water immersions.
SPECIFICATIONS
Max Flow984 L/Min
Max Head7.2 m
Power1.1 kW / 415v
Rated Current2.9 Amps
Suitable ForVolumetric Raw Sewage
Body MaterialCast Iron
Liquid TemperatureMaximum 40°C
Inlet Size80 mm
Outlet Size100 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Data Sheet Download
Installation Guide Download
Data Booklet Download
Service Instructions Download

Circulating light wastewater through civil drainage vaults, The Grundfos SLV.80.100.11.4.50B.C maintains dependable outflow. Subterranean collection pits rely on this four-pole unit to route fluid into municipal sewers.

  • Civil Drainage Vaults
  • Subterranean Collection Pits
  • Municipal Sewers

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Installation Guide
Download
Data Booklet
Download
Service Instructions
Download
During high-volume storm runoff, what maximum liters per minute are discharged?

Submerged pumping terminals utilize Grundfos SLV.80.100.11.4.50B.C to displace fluid at 984 L/Min.

During high-pressure pumping duty, what peak head is developed by this assembly?

Peak vertical head capacity is rated at 7.2 m for SLV.80.100.11.4.50B.C.

Sustaining heavy-duty drainage, what motor power rating, line voltage connection, and full-load current draw support this unit?

Supplied with three-phase utility power, SLV-80-100-11-4-50B-C runs a 1.1 kW motor across a three-phase 415 V line at 2.9 Amps.

In civil infrastructure sumps, what free through-let dimension accommodates unscreened wastewater across this vortex casing?

Casing through-let metrics for SLV 80 100 11 4 50B C certify a 80 mm spherical clearance supported by its recessed SuperVortex profile.

Firmly seating the volute base, what auto-coupling assembly connects this high-volume pump firmly to permanent station piping?

Permanent riser connections remain undisturbed while SLV/80/100/11/4/50B/C is extracted from its auto-coupling mounting base.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed