Grundfos SLV.80.100.75.2.50B.C Cast Iron 2-Pole Submersible Pump for Heavy Wastewater with SuperVortex Impeller
SKU: 98625963

Grundfos SLV.80.100.75.2.50B.C Cast Iron 2-Pole Submersible Pump for Heavy Wastewater with SuperVortex Impeller

$11,159.23 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1836 L/Min
Max Head
32.5 m
Power
7.5 kW / 415v
Ideal Use
High-Volume Abrasive Fluid

Product Overview

Addressing critical municipal scaling and stringent safety containment, the SLV.80.100.75.2.50B.C relies strictly upon its 100 mm outlet design. This exceptionally rugged framework actively curtails expensive downtime across harsh fluid networks by definitively averting destructive internal friction over continuous long-term runtimes.

The robust structure heavily anchors an unhindered fluid corridor distinctly tailored for density optimization. Heavy debris travels into an 80 millimeter suction connection and forcefully expands out of the reinforced 100 millimeter discharge opening, relentlessly preserving the mechanical integrity of the core operational boundaries.

Processing immense volumetric demands flawlessly, this machine overcomes severe fluid tension utilizing a precise 3-phase 415v electrical matrix. Regulating 14.9 Amps to harness a massive 7.5 kW power input, the drive powerfully propels an approximate maximum flow volume of 1836 L/Min across complex piping structures easily.

Dominating severe forces during intense subterranean deployments, the rotational mechanism forces extremely dense waste vertically to confidently overcome an approximate maximum head measuring 32.5 meters. Integrated PTC thermal switches autonomously monitor the motor winding matrix to eliminate destructive internal temperature spikes safely.

Features

  • Engineered strictly with an efficient SuperVortex impeller strategically calibrated to safely allow the passage of long fibres and solid materials up to 80 millimeters.
  • Constructed utilizing a unique stainless-steel clamp assembling system that definitively guarantees rapid field disassembly for mandatory service and visual inspections.
  • Relies deeply on a high-endurance silicon carbide primary shaft seal configuration (SIC/SIC) to flawlessly protect isolated internal electrical chamber integrity.
  • Features a premium industrial IP68 rated waterproof enclosure class paired exceptionally with an H thermal insulation class motor for immensely superior operational defense.
  • Flawlessly calibrated to spin steadily at a rapid 2921 rpm, powerfully balancing intense raw suspended flow propulsion with unparalleled mechanical structural longevity.
  • Supplied securely out of the box with a flexible 10 meter LYNIFLEX electrical cable entirely jacketed to comfortably survive deep subterranean chemical liquid exposures.
SPECIFICATIONS
Max Flow1836 L/Min
Max Head32.5 m
Power7.5 kW / 415v
Rated Current14.9 Amps
Suitable ForHigh-Volume Abrasive Fluid
Body MaterialCast Iron
Liquid TemperatureMaximum 40°C
Inlet Size80 mm
Outlet Size100 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Data Sheet Download
Installation Guide Download
Data Booklet Download
Service Instructions Download

Positioned in demanding wet well sumps, The Grundfos SLV.80.100.75.2.50B.C delivers dependable fluid movement for civil wastewater infrastructure. Deep underground pump rooms utilize this submerged assembly to circulate untreated effluents cleanly.

  • Civil Infrastructure Vaults
  • Underground Pump Rooms
  • Sewage Networks

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Installation Guide
Download
Data Booklet
Download
Service Instructions
Download
What maximum volumetric flow throughput is maintained per minute during peak station cycles?

Under peak community usage hours, Grundfos SLV.80.100.75.2.50B.C maintains an evacuation rate of 1836 L/Min.

In deep subterranean wastewater vaults, what maximum vertical head does this pump reach?

Discharge pressure ratings confirm SLV.80.100.75.2.50B.C achieves an operational head of 32.5 m.

With utility electrical feeds, which electrical specifications, supply line parameters, and running current drive this large unit?

Operational electrical data for SLV-80-100-75-2-50B-C confirms a 7.5 kW motor drawing 14.9 Amps on a three-phase 415 V supply.

Displacing raw community effluent, how does the vortex fluid vortex create clear passage corridors for unscreened municipal solids?

Minimizing runner contact, SLV 80 100 75 2 50B C utilizes a 80 mm vortex corridor to sweep solids through the SuperVortex casing.

In massive subterranean vaults, which guide rail mounting configuration supports submerged installation in high-capacity sumps?

Automated pit docking occurs when SLV/80/100/75/2/50B/C reaches the bottom of the guide rails and engages the auto-coupling bracket.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed