Calpeda BS2V 2MXV 65-3210-ITT 2 x 18.5kW Variable Speed Twin Pump Booster Set with I-MAT Converter
SKU: BS2V 2MXV 65-3210-ITT

Calpeda BS2V 2MXV 65-3210-ITT 2 x 18.5kW Variable Speed Twin Pump Booster Set with I-MAT Converter

$67,276.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Calpeda
24 Months
Peace of Mind
Max Flow
1467 L/Min
Max Head
172 m
Power
2 x 18.5 kW / 415v
Ideal Use
Centralized Potable Water Reticulation

Product Overview

Maintaining uniform delivery pressure across extensive commercial developments demands steady and balanced hydraulic support. Built with 2 Calpeda MXV 65-3210 vertical multistage pumps operating in a parallel staging arrangement, this variable-speed twin package ensures continuous pressure stability. At peak consumption, the dual-pump configuration produces a peak volumetric flow rate of 1467 L/Min to sustain commercial operations. Under closed-valve conditions, the vertical multistage stacks develop a maximum shut-off head of 172 m to overcome vertical building height.

Precise setpoint pressure is sustained across fluctuating facility draw through an integrated motor-mounted Calpeda I-MAT variable frequency converter. An electronic pressure transducer continuously feeds line data to the integrated controller, modulating pump speed to deliver exact flow requirements without pressure spikes. Smooth soft-start and soft-stop ramp profiles protect building distribution pipework from mechanical water hammer and sudden pressure waves. Built-in electronic monitoring systems deliver automatic safety shutdown protection in the event of dry-run conditions, electrical phase imbalance, or motor overload.

Constructed with Cast Iron GJL 250 hydraulic casings and AISI 304 stainless steel wet ends, the pumps deliver outstanding mechanical durability under continuous high-pressure service. Hydraulic flow distributes through common stainless steel manifolds with standardized 100 mm suction and 100 mm delivery fittings with DN 100 flanged. Independent isolation valves and check valves service each pump run, mounted alongside an analog delivery pressure gauge upon an AISI 304 stainless steel baseplate frame.

Synchronous mechanical output is supplied by two 2-pole commercial induction motors matched to Australian three-phase 400 V (50 Hz) power standards. Rotating at a nominal operating speed of 2900 rpm, the twin motor assembly delivers 2 x 18.5 kW of total drive power while drawing a rated full-load current of 2 x 34 Amps. High-efficiency motor design maintains balanced electrical consumption and robust mechanical performance across varying commercial pressure demands.

Key Features

  • Synchronized dual vertical multistage 10-stage hydraulic wet ends operate in parallel to produce smooth and balanced line pressure.
  • An integrated motor-mounted Calpeda I-MAT variable frequency converter continuously modulates operating speed to sustain exact setpoint pressure.
  • Heavy-duty Cast Iron pump casings paired with AISI 304 stainless steel stage chambers and impellers deliver exceptional structural rigidity.
  • Weatherproof electric motor enclosures are sealed to IP55 standards with Class F thermal winding insulation for demanding plant room environments.
  • Verified operating limits safely circulate clean commercial liquids across a working temperature spectrum of -15 °C to +110 °C.
  • Controlled acceleration and deceleration ramp profiles eliminate sudden pressure spikes and safeguard building pipework from water hammer.
  • Integrated digital safety electronics provide automated shutdown protection against dry-running, motor overcurrent, and electrical supply faults.
  • Standardized DN 100 flanged manifold connections simplify mechanical alignment and expedite site pipework installation.
  • Automated duty assist rotation equalizes operating run hours across both pumps to prevent uneven component wear.
  • Backed by a standard 24-month manufacturer warranty.

What's Included

  • 2 x Calpeda MXV 65-3210 vertical multistage pumps
  • 1 x Motor-mounted Calpeda I-MAT variable frequency converter with motor adapter and interconnect cabling
  • 1 x Factory-mounted 18 L membrane pressure vessel on delivery manifold
  • 1 x AISI 304 stainless steel suction manifold with individual isolation ball valves and non-return valves
  • 1 x AISI 304 stainless steel delivery manifold with individual isolation ball valves and visual pressure gauge
  • 1 x Digital electronic pressure transducer pre-wired to the I-MAT inverter system
  • 1 x Heavy-duty AISI 304 stainless steel structural mounting baseplate
SPECIFICATIONS
Max Flow1467 L/Min
Max Head172 m
Power2 x 18.5 kW / 415v
Rated Current2 x 34 Amps
Suitable ForCentralized Potable Water Reticulation
Body MaterialCast Iron
Liquid Temperature-15°C to +110°C
Inlet Size100 mm
Outlet Size100 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Data Sheet Download
Operating Instructions Download
I-MAT Operating Instructions Download
Spare Parts Exploded View Download

Commercial property maintenance teams specify the Calpeda BS2V 2MXV 65-3210-ITT twin booster set for balanced water pressure distribution across multi-level infrastructure. Built with 2 x Calpeda MXV 65-3210 vertical multistage pump assemblies, the package delivers a maximum volumetric flow rate of 1467 L/min to overcome sudden demand spikes across commercial pipework. The high-efficiency vertical hydraulic stacks produce a maximum shut-off head of 172 metres to maintain constant vertical static elevation without line starvation.

  • High-Flow Commercial Water Boosting
  • Multi-Tower Building Water Supply
  • Centralized Potable Water Reticulation
  • Commercial Industrial Water Boosting

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Operating Instructions
Download
I-MAT Operating Instructions
Download
Spare Parts Exploded View
Download
What manufacturer warranty coverage supports this twin booster package?

The BS2V 2MXV 65-3210-ITT is backed by a standard 24-month manufacturer warranty covering the pumping system.

What peak water discharge rate and maximum parallel flow capacity does this package supply?

Under peak distribution demand, the BS2V 2MXV 65-3210-ITT supplies up to 1466.6 L/min (88 m³/h) across dual pumps, where each multistage pump provides up to 733.3 L/min (44 m³/h).

Which electrical power supply and variable speed frequency converter regulate this booster set?

Electrical propulsion for the BS2V-2MXV-65-3210-ITT draws Three Phase 400 V power at 50 Hz, energizing twin 18.5 kW (25 HP) electric motors totaling 37 kW modulated by an integrated Calpeda I-MAT variable frequency converter.

Under what maximum static head elevation and line pressure limits does this package operate?

Within elevated discharge circuits, the BS2V 2 MXV 65 3210 ITT generates up to 172 metres of head and accommodates casing pressures up to 25 bar across temperatures from -15 °C to +110 °C.

What corrosion proof wetted metallurgy and common manifold connection sizes are incorporated?

Physical metallurgy across the 2MXV 65-3210-ITT encompasses Cast iron GJL 250 pump casings, AISI 304 stage casings, and AISI 304 stainless steel impellers on a Zinc-plated Steel S235JR Baseplate, with DN 100 Flanged suction and DN 100 Flanged delivery common manifolds.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed