Lowara 5HM17S30T Stainless Steel Resilient Multistage Centrifugal Pump for Fluid Delivery with Closed Impeller
SKU: 5HM17S30T

Lowara 5HM17S30T Stainless Steel Resilient Multistage Centrifugal Pump for Fluid Delivery with Closed Impeller

$2,890.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
142 L/Min
Max Head
125 m
Power
3 kW / 415v
Ideal Use
Process Water Handling

Product Overview

Navigating complex industrial fluid delivery demands a solution that balances material resilience with operational precision. The Lowara 5HM17S30T addresses these needs by combining a compact, high-efficiency horizontal architecture with construction materials suitable for aggressive or high-demand water transfer. It serves as a cornerstone for circulation loops where pressure stability is critical, ensuring seamless performance within varied mechanical setups. The unit is engineered to integrate fluidly into existing piping arrays, allowing for direct installation into standard supply frameworks where spatial constraints often dictate equipment choice.

Performance parameters are governed by an IE3 energy-efficient motor capable of sustaining consistent hydraulic output. Operational threshold limits are defined by a Max Head 125 m alongside a Max Flow 142 L/Min. Rated at 3 kW / 415v, the system maintains stable pressure-flow characteristics even under fluctuating load conditions, minimizing energy consumption while maximizing volumetric efficiency during prolonged operation cycles.

Fluid dynamics are governed by a multi-stage closed impeller arrangement fabricated from AISI 304 stainless steel. This design ensures that hydraulic energy is converted with minimal internal turbulence, promoting smooth flow across all stages of the pump body. The internal geometry is specifically refined to optimize suction side efficiency, allowing the unit to maintain steady throughput without cavitation risk, effectively stabilizing circulation within closed-loop thermal or process systems.

Housing integrity is provided by an AISI 304 stainless steel casing, designed for compatibility with liquid temperatures ranging from -10°C to +120°C. The motor features an IP 55 protection rating, shielding internal components from dust and moisture ingress, while the electric pump assembly holds an IP X5 rating. All seals utilize high-grade elastomer materials, ensuring long-term leakage resistance and alignment with diverse industrial safety standards for clean water handling and chemical-process circulation.

Features:

  • TEFC 2-pole surface motor configuration for consistent operational stability
  • Short-circuit squirrel-cage rotor design reducing total system maintenance needs
  • Silicon carbide mechanical seal faces for improved chemical and abrasion resistance
  • Class 155 insulation standards safeguarding against high-temperature motor stress
  • Standardized 32mm suction and 25mm delivery port sizes for simplified plumbing
  • TIG welded structural sleeve housing for enhanced pressure containment performance
SPECIFICATIONS
Max Flow142 L/Min
Max Head125 m
Power3 kW / 415v
Rated Current5.64 Amps
Suitable ForProcess Water Handling
Body MaterialAISI 304 Stainless Steel
Liquid Temperature-10°C to +120°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

Closed-loop thermal systems and process-water circuits benefit from reliable circulation where clean or demanding liquids must remain in steady movement. The Lowara 5HM17S30T suits these applications alongside high-demand water-transfer duties requiring dependable pressure.

  • Closed-loop Cooling
  • Process Water
  • Thermal Circulation
  • Water Transfer

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
Which alloy materials and mechanical seal metallurgy guard against corrosion inside this booster?

Corrosion-resistant construction on the 5HM17S30T combines AISI 304 stainless steel pump casing, diffusers, and closed impellers with mechanical face seals to prevent chemical attack.

In terms of electrical drive, what kilowatt power rating and operating voltage feed are utilized?

The power drive of the 5HM-17S-30T features a 3 kW (4.0 HP) motor operating at 380–415 V, 50 Hz, three-phase with current demand of 5.64 A.

To protect casing integrity, what liquid operating temperature limits and maximum working pressure apply?

High pressure containment on the 5HM 17S 30T is rated for a maximum working pressure limit of 16 bar (PN 16) with fluid temperature capabilities from -10°C to +120°C.

How many meters of dynamic elevation head can this multistage booster elevate upward?

Overcoming elevation resistance across pipework, the 5HM_17S_30T provides a maximum dynamic head of approximately 125 m.

In distribution plumbing lines, what peak delivery flow volume and port size are engineered here?

Discharge plumbing connections of Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge allow the 5HM17S30T to output a maximum delivery flow volume of approximately 142 L/Min.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us