Lowara NSCS65 200/150 Cast Iron Horizontal Centrifugal Pump for Pressure Regulation with Closed Impeller
SKU: NSCS65-200/150

Lowara NSCS65 200/150 Cast Iron Horizontal Centrifugal Pump for Pressure Regulation with Closed Impeller

$8,374.63 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
2304 L/Min
Max Head
42.8 m
Power
15 kW / 415v
Ideal Use
HVAC Circulation

Product Overview

Commercial water supply networks rely on stable pressure regulation to distribute utility liquids across expansive infrastructure. The Lowara NSCS65-200/150 high-capacity centrifugal unit acts as a mechanical driver for industrial water boosting, ensuring steady fluid delivery for centralized layouts.

Performance specifications highlight a maximum head rating of approximately 42.8 m alongside a peak delivery capacity of 2304 L/Min. Driven by a 15 kW electric motor, this unit operates on a 415v three-phase power supply and draws 26.1 Amps. Plumbing connections are sized at 80 mm for suction and 65 mm for discharge.

A precision-cast rotating assembly directs incoming liquid to manage exit acceleration while dampening internal vibration. This end-suction layout balances applied centrifugal forces, which helps keep utility circulation steady regardless of minor fluctuations in system resistance.

Engineered to process liquid environments from -25°C to +120°C, the core wetted elements are constructed using durable cast iron. The external architecture utilizes structural bracing and an enclosed motor shield to protect sensitive electrical components from factory exposure.

FEATURES

  • Solidly linked drive extension ensures aligned rotational movement under standard system strain
  • Strategic back pull-out architecture minimizes service downtime by isolating the internal rotating elements
  • Precision-machined casing cover limits microscopic bypass to maintain target system pressure
  • Industrial squirrel cage motor construction supports continuous-duty reliability
  • DN80 and DN65 standardized bolting flanges simplify the attachment of commercial pipework
  • Precision-welded hydraulic geometry addresses internal cavitation risks during sustained operation
  • IP55-rated external enclosure repels airborne moisture and facility dust
SPECIFICATIONS
Max Flow2304 L/Min
Max Head42.8 m
Power15 kW / 415v
Rated Current26.1 Amps
Suitable ForHVAC Circulation
Body MaterialCast Iron
Liquid Temperature-25°C to +120°C
Inlet Size80 mm
Outlet Size65 mm
Warranty12 Months
Documents
Specification Datasheet Download
Quick Startup Guide Download
Operating Manual Download

Large water distribution systems require stable transfer from central sources through extensive plumbing networks. The Lowara NSCS65-200/150 suits water boosting, facility supply and multi-branch distribution systems serving broad service areas.

  • Water Boosting
  • Facility Supply
  • Multi-Branch Distribution
  • Plumbing Systems

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Quick Startup Guide
Download
Operating Manual
Download
Which maximum upward dynamic head is produced when operating this flanged end-suction centrifugal pump?

Driving across building service lines, the NSCS65-200/150 attains a peak dynamic elevation head of approximately 42.8 m propelling fluid upward.

Regarding fluid transfer volume, what maximum delivery flow and connection port dimensions apply to this flanged end-suction centrifugal pump?

Routing across facility piping networks, the NSCS65-200-150 sustains a maximum delivery flow capacity of approximately 2304 L/Min plumbed with DN 80 suction and DN 65 discharge flanged ports.

To protect against chemical attack, what alloy metallurgy and mechanical seals are incorporated into this flanged end-suction centrifugal pump?

Equipped with corrosion-resistant alloy materials, the NSCS65 200 150 features metallurgy of cast iron casing with stainless steel closed impellers complemented by precision mechanical seals to eliminate corrosion leaks.

Under nominal electrical service, what electrical supply voltage and motor kilowatt power support this flanged end-suction centrifugal pump?

Running by facility power panels, the NSCS65_200_150 is driven by an electric motor rated at 15 kW (20.0 HP) powered by 380–415 V, 50 Hz, three-phase drawing 26.1 A.

Regarding pressure boundaries, what maximum working pressure rating and liquid temperature range govern this flanged end-suction centrifugal pump?

Approved under demanding fluid temperatures, the NSCS65-200/150 withstands a maximum working pressure limit of 16 bar (PN 16) with fluid temperatures ranging from -25°C to +120°C.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed