DAB GENIX-WL-110 Barium PP Macerator Lifting Station for Wall-Hung Infrastructure with Side Intake
SKU: 807406

DAB GENIX-WL-110 Barium PP Macerator Lifting Station for Wall-Hung Infrastructure with Side Intake

$1,589.50 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official DAB
24 Months
Peace of Mind
Max Flow
115 L/Min
Max Head
6 m
Power
0.32 kW / 240v
Ideal Use
Wall-hung toilet + 1 Washbasin

Product Overview

Focused on structural safety and operating cost scaling, the DAB GENIX WL 110 lifting station offers a specific solution for architectural layouts. This unit is engineered with a side-oriented toilet connection, making it ideal for wall-hung sanitary fixtures where rear clearance is non-existent. Facilities can maximize their usable square footage.

Formed from durable thirty percent barium reinforced polypropylene, the containment tank handles continuous mechanical stress. The integrated motor assembly utilizes a resilient stainless steel drive shaft. This environment ensures raw waste is broken down safely by the internal shredder, effectively preventing municipal blockages.

Operating at an efficient 2.3 Amps on a standard 240v connection, the system converts 0.32 kW of input power into robust hydraulic output. The internal PPO fiberglass impeller is calibrated to generate a maximum flow capacity of 115 L/Min. Pushing fluid vertically against a 6 meter maximum head, it easily overcomes gravity.

To protect indoor environments from unsanitary conditions, the platform features a specialized anti-odour system built directly into the casing. Internal non-return valves guarantee that expelled water cannot siphon back into the primary chamber. Weighing 10 kilograms, the structure uses quick-connect fittings to anchor effortlessly. The unit is certified to EN 12050-3 with IP44 protection.

Features

  • Specifically configured with a side toilet connection intended to accommodate modern wall-hung sanitary fixtures
  • Constructed from specialized thirty percent barium reinforced polypropylene to resist mechanical tank warping
  • Generates a stable 115 L/Min maximum flow capability while drawing only 2.3 Amps of electrical current
  • Engineered to overcome challenging elevation changes with a certified 6 meter maximum vertical discharge head
  • Incorporates a highly resilient nickel-plated steel shredder to rapidly process organic matter without motor stalling
  • Arrives fully equipped with reliable non-return valves and vibration dampening rubber nubs for quiet daily operation
  • Certified to EN 12050-3 with IP44 protection class
SPECIFICATIONS
Max Flow115 L/Min
Max Head6 m
Power0.32 kW / 240v
Rated Current2.3 Amps
Suitable ForWall-hung toilet + 1 Washbasin
Body Material30% Barium-Reinforced Polypropylene
Liquid TemperatureMaximum 50°C
Outlet Size22 mm to 40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Data Sheet Download
Installation Manual Download
Spare Parts Information Download

Wall-hung sanitary fixtures layouts can require a pumped drainage route when gravity flow or rear clearance is limited. DAB GENIX-WL-110 collects sanitary waste and transfers it toward the drainage connection, helping serve washroom facilities installations with restricted pipework space.

  • Sanitary Waste Lifting
  • Restricted Space Drainage
  • Remote washroom facilities Drainage
  • Wall Hung sanitary fixtures

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Installation Manual
Download
Spare Parts Information
Download
Which power supply and motor output operate this lifting station?

Electrical input comes from a single-phase 240V supply and DAB GENIX-WL-110 draws 2.3 A to run its 0.32 kW motor during wastewater lifting.

What maximum flow capacity is available for wastewater transfer?

Wastewater flow reaches up to 115 L/Min and DAB-GENIX-WL-110 has a separate maximum vertical head of 6 m for elevated drainage.

Which toilet installation does the station accommodate?

A side-oriented toilet connection suits wall-hung sanitary fixtures where rear clearance is unavailable and DAB/GENIX/WL/110 incorporates an internal shredder for waste processing.

Which tank material is used to resist structural warping?

The containment tank uses polypropylene reinforced with thirty percent barium and DAB_GENIX_WL_110 includes non-return valves to stop wastewater returning into the chamber.

What certification and protection rating apply to this model?

EN 12050-3 certification and IP44 protection apply to the lifting station while DAB GENIX WL 110 includes a built-in anti-odour system.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed