Reliable automated drainage in civil pits is provided by the Calpeda GXVM 25-10 GFA. This submersible pump is equipped with a vertical magnetic float switch, enabling automatic operation in narrow wells or tanks where space is at a premium. It is designed for managing clean or dirty water with suspended solids up to 25 mm at liquid temperatures not exceeding 50°C.
Powered by a 0.45 kW single-phase 240v motor, the model delivers a maximum flow rate of 220 L/min and reaches a maximum head of 9.5 m. Operating with a rated current of 4.5 Amps, the pumped liquid dissipates motor heat during operation. This thermal management design permits safe continuous duty performance even when the unit is only partially submerged in pits.
Water passes through a single vortex impeller arranged to move clean or slightly dirty liquids with high efficiency and clog resistance. The suction filter is integrated into the AISI 304 stainless steel pump body, and the vertical delivery port facilitates direct connection to discharge pipework. For automatic service, the magnetic switch requires a minimum water level of 130 mm.
The close-coupled construction features motor and pump jackets manufactured from chrome-nickel stainless steel AISI 304. Sealing is achieved using a double mechanical shaft seal with an oil chamber housing oil for food and pharmaceutical machinery. This single-phase unit includes a built-in thermal protector, incorporated capacitor, and a triple impregnation humidity-proof dry winding.
FEATURES
- Equipped with a vertical magnetic float switch for automatic operation in tight collection pits and tanks.
- Manufactured with all internal and external components in contact with fluid in chrome-nickel stainless steel AISI 304.
- Double mechanical shaft seal with an oil-filled chamber protects the motor against water ingress and wear.
- Mechanical shaft seal lubrication is ensured by pharmaceutical-grade oil within the integrated oil chamber.
- Internal cooling is achieved by fluid circulating between the motor jacket and outer shell during operation.
- Free-flow vortex impeller design facilitates handling of water containing solids up to 25 mm in grain size.
- Motor winding is a triple impregnation humidity-proof dry type constructed in accordance with EN 60335-2-41.
- Suitable for continuous duty operation with IPX8 protection for immersion at depths up to 5 meters.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What level is needed before the magnetic float switch activates?
The magnetic float switch on GXVM_25_10_GFA requires a minimum water level of 130 mm before automatic drainage starts in collection pits.
What maximum vertical delivery head can be reached?
A 9.5 m maximum head is available from GXVM 25-10 GFA for domestic and civil drainage applications in collection pits.
What type of impeller handles suspended solids?
A free-flow vortex impeller on GXVM-25-10-GFA handles clean or slightly dirty water containing suspended solids up to 25 mm, for drainage duties.
How much power and current does its motor use?
Rated at 0.45 kW, the single-phase 240V motor on GXVM/25/10/GFA draws 4.5 Amps during automated drainage from tanks and pits.
Which protection rating covers continuous pump immersion?
The IPX8 enclosure rating allows continuous immersion to 5 meters on GXVM 25 10 GFA, supplied with a 10 m power cable.