Ebara 2CDXM 120/15 Stainless Steel High Flow Centrifugal Pump for Cooling Water with Twin Impeller
SKU: 162115-7600B

Ebara 2CDXM 120/15 Stainless Steel High Flow Centrifugal Pump for Cooling Water with Twin Impeller

$1,407.18 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Ebara
12 Months
Peace of Mind
Max Flow
150 L/Min
Max Head
42 m
Power
1.1 kW / 240v
Ideal Use
Cooling water

Product Overview

Cooling water circulation in industrial systems requires stable flow delivery and consistent hydraulic performance, making this pump suitable for cooling loops, heat exchange circuits, and recirculation setups. It supports clean water applications where continuous flow and operational reliability are essential.

Operating with a maximum flow of 150 L/Min and a head reaching 42 m, the pump provides strong flow capacity while maintaining steady pressure characteristics. This allows efficient circulation and reliable performance across varying load conditions in cooling applications.

A twin closed impeller configuration develops pressure progressively through staged operation, enabling efficient hydraulic performance. This design ensures smooth flow transition, reduces internal recirculation, and maintains consistent discharge behavior during continuous operation.

The construction incorporates 304 stainless steel hydraulic components including casing, impellers, and diffuser for corrosion resistance. A close coupled configuration reduces installation space, while the back pull-out construction allows servicing without disturbing pipework. The Carbon/Ceramic/NBR mechanical seal ensures dependable sealing performance under standard operating conditions.

FEATURES
  • Twin closed impeller system enabling efficient staged pressure development
  • Back pull-out construction allowing maintenance without pipe disconnection
  • Close coupled configuration ensuring compact installation and alignment
  • Top centerline discharge supporting natural air venting during operation
  • Foot-mounted casing support reducing stress from piping loads
  • Hydraulic diffuser ensuring controlled flow between impeller stages
  • Sealed ball bearing system maintaining shaft stability and rotation accuracy
  • TEFC motor with IP55 enclosure and Class F insulation
SPECIFICATIONS
Max Flow150 L/Min
Max Head42 m
Power1.1 kW / 240v
Rated Current8.3 Amps
Suitable ForCooling water
Body Material304 Stainless Steel
Liquid TemperatureMaximum 60°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification DataSheet Download
Instruction Manual Download

Industrial cooling circuits can use the Ebara 2CDXM 120/15 for circulation through cooling loops and heat-exchange circuits. Its description also identifies recirculation setups, where stable clean-water flow is required to move water continuously around the process system.

  • Heat Exchanger Circulation
  • Cooling Water Circulation
  • Cooling Loop Circulation
  • Water Circulation

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification DataSheet
Download
Instruction Manual
Download
What maximum head is available for industrial circulation?

For industrial cooling circuits the maximum head of 42 m is available from 2CDXM_120_15, supporting heat-exchange and recirculation pipework in continuous-duty systems.

Which cooling applications suit this twin-impeller pump?

Cooling loops, heat-exchange circuits and recirculation setups suit 2CDXM 120 15 where continuous clean-water flow is needed for industrial operation.

Can servicing proceed without disconnecting the installed pipework?

Scheduled maintenance can reach the internal assembly of 2CDXM-120-15 through its back pull-out layout without disconnecting connected pipework from the installed system.

What maximum flow is available for industrial circulation?

Industrial circulation receives a maximum flow of 150 L/Min from 2CDXM/120/15, supporting cooling loops and heat-exchange circuits under continuous operating conditions.

Which sealing materials are fitted for standard operation?

For standard-duty sealing, the Carbon/Ceramic/NBR mechanical seal is fitted to 2CDXM12015, helping limit leakage at the shaft during normal operation.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed