Max Flow
80 L/Min
Max Head
44.5 m
Power
0.75 kW / 240v
Ideal Use
Water Circulation

Product Overview

Where stable pressure delivery is required in building services and water circulation networks, this pump supports water pressure systems, HVAC loops, and process distribution lines handling clean water. It is applied in installations where consistent discharge and reliable system balancing are essential for operational continuity.

With capacity reaching up to 80 L/Min and head performance extending to 44.5 m, the pump operates effectively across moderate flow ranges while maintaining strong pressure output. This performance profile supports applications requiring sustained head without fluctuations under varying demand conditions.

Flow is supported through a twin closed impeller arrangement that progressively increases pressure across stages, enabling efficient head development. The hydraulic configuration ensures controlled flow passage, reduced internal recirculation, and stable delivery characteristics across the operating range.

The construction incorporates 304 stainless steel hydraulic components including casing, impellers, and diffuser, providing corrosion resistance and durability. A close coupled configuration reduces installation footprint, while the back pull-out design allows internal servicing without disturbing pipework. The standard Carbon/Ceramic/NBR mechanical seal ensures dependable sealing under normal liquid temperature limits.

FEATURES
  • Twin closed impeller configuration enabling staged pressure generation
  • Back pull-out design allowing seal and impeller access without pipe removal
  • Close coupled motor-pump assembly minimizing alignment requirements
  • Top centerline discharge supporting automatic air venting during operation
  • Rigid foot support under casing reducing pipe-induced stress
  • Hydraulically optimized diffuser for guided flow transition between stages
  • Precision shaft support with sealed ball bearings for rotational stability
  • TEFC motor construction with IP55 enclosure and Class F insulation
SPECIFICATIONS
Max Flow80 L/Min
Max Head44.5 m
Power0.75 kW / 240v
Rated Current7 Amps
Suitable ForWater Circulation
Body Material304 Stainless Steel
Liquid TemperatureMaximum 60°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification DataSheet Download
Instruction Manual Download

For the Ebara 2CDXM 70/12, where stable pressure delivery is required in building services and water circulation networks, this pump supports water pressure systems, HVAC loops, and process distribution lines handling clean water. It is applied in installations where consistent discharge and reliable system balancing are essential for operational continuity.

  • HVAC Circulation
  • Building Water Supply
  • Process Water Transfer
  • Water Pressure Systems

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification DataSheet
Download
Instruction Manual
Download
How does its twin-impeller arrangement increase discharge pressure?

The 2CDXM_70_12 uses twin closed impellers arranged in stages to build pressure progressively while supporting smooth liquid movement during operation.

Which building-service duties suit this centrifugal pump?

Water-pressure systems HVAC circulation loops and process distribution lines can use the 2CDXM 70 12 for clean-water handling and stable discharge.

What maximum flow capacity is stated for transfer?

Up to 80 L/Min is available from the 2CDXM-70-12 for circulation networks that require moderate flow with sustained pressure delivery.

What maximum head is available in operation?

The 2CDXM/70/12 reaches a maximum head of 44.5 m for clean-water systems requiring higher discharge pressure across moderate flow conditions.

Which construction features simplify routine pump servicing?

AISI 304 casing impellers and diffuser form the 2CDXM7012 wetted construction while back pull-out access supports servicing without pipe disconnection.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed