Ebara 2CDXM 70/12 Stainless Steel High Temperature Centrifugal Pump for Heat Exchange with Twin Impeller
SKU: 161112-7500-HT

Ebara 2CDXM 70/12 Stainless Steel High Temperature Centrifugal Pump for Heat Exchange with Twin Impeller

$1,575.48 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Ebara
12 Months
Peace of Mind
Max Flow
80 L/Min
Max Head
44.5 m
Power
0.75 kW / 240v
Ideal Use
Heat Exchanger

Product Overview

Where controlled fluid movement is required in thermal exchange processes, this pump is used in heat exchanger systems, cooling circuits, and process circulation loops handling clean water. It supports installations where stable flow and pressure are essential for efficient heat transfer and system balance.

With capacity reaching up to 80 L/Min and head performance extending to 44.5 m, the pump maintains consistent hydraulic output across its operating range. This ensures effective circulation and pressure stability in systems where maintaining flow continuity is critical for thermal efficiency.

Flow is developed through a twin closed impeller configuration that operates in series, enabling multistage pressure build-up. This design improves hydraulic efficiency while maintaining smooth flow transition between stages, ensuring stable discharge and reduced internal losses during operation.

The construction incorporates 304 stainless steel hydraulic components including casing, impellers, and diffuser, providing corrosion resistance in demanding environments. A close coupled arrangement minimizes installation space, while the back pull-out construction allows maintenance without disturbing connected piping. The high temperature Carbon/Ceramic/Viton mechanical seal supports reliable operation under elevated liquid temperatures.

FEATURES
  • Multistage twin impeller system enabling progressive pressure generation
  • Back pull-out construction for maintenance without pipeline removal
  • Close coupled configuration ensuring compact installation and alignment stability
  • Top centerline discharge supporting effective self-venting operation
  • Foot-mounted casing support reducing mechanical stress from pipe loads
  • Integrated diffuser design optimizing interstage flow control
  • Sealed ball bearing system ensuring stable shaft operation
  • TEFC motor design with IP55 enclosure and Class F insulation
SPECIFICATIONS
Max Flow80 L/Min
Max Head44.5 m
Power0.75 kW / 240v
Rated Current7 Amps
Suitable ForHeat Exchanger
Body Material304 Stainless Steel
Liquid TemperatureMaximum 110°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification DataSheet Download
Instruction Manual Download

In thermal systems, the Ebara 2CDXM 70/12 provides clean-water circulation and pressure supply for Clean Water Circulation and Process Circulation. Its twin-impeller centrifugal arrangement is suited to these duties and can also support Cooling Water Circulation and Heat Exchanger Circulation.

  • Heat Transfer Systems
  • Process Circulation
  • Cooling Water Circulation
  • Heat Exchanger Circulation

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification DataSheet
Download
Instruction Manual
Download
How does the pump simplify internal maintenance access?

Internal service access remains straightforward because the 2CDXM_70_12_HT uses back pull-out construction allowing maintenance without disturbing connected pipework. during scheduled internal service work

Which heat-transfer applications are suitable for this pump?

Heat exchanger systems cooling circuits and process circulation loops can use the 2CDXM 70 12 HT for clean-water transfer with stable pressure.

What maximum head is stated for circulation?

The 2CDXM-70-12-HT develops a maximum head of 44.5 m for thermal exchange installations that need consistent discharge pressure. for heated clean-water circulation

How does the twin-impeller arrangement build pressure?

Twin closed impellers in the 2CDXM/70/12/HT operate in series to build pressure progressively while maintaining smooth flow between hydraulic stages.

Which seal and wetted materials are included?

AISI 304 stainless steel forms the casing impellers and diffuser while a Carbon/Ceramic/Viton seal equips the 2CDXM7012HT for elevated-temperature service.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed