Product Overview
Where systems require continuous circulation of heated clean water, this pump supports heating systems, thermal loops, and controlled circulation networks operating at elevated temperatures. Its configuration is suited to installations where steady flow and thermal resistance are essential for consistent system performance.
With flow reaching up to 180 L/Min and a maximum head of 20.5 meters, the unit delivers stable hydraulic performance across its operating range. The performance curve ensures smooth pressure distribution with consistent flow behavior under varying thermal load conditions.
Flow is supported through a closed centrifugal impeller that directs liquid efficiently while minimizing internal recirculation losses. This hydraulic design ensures stable discharge characteristics and reliable flow handling in clean water circulation systems.
The construction incorporates AISI 304 stainless steel for the casing, impeller, and casing cover, combined with a 303 stainless steel shaft. The high temperature version is equipped with a Carbon/Ceramic/Viton mechanical seal and Viton O-rings, enabling operation up to 110°C, while the TEFC motor with IP55 protection and Class F insulation supports dependable continuous-duty operation with built-in overload protection.
FEATURES- High temperature seal configuration with Viton elastomers for thermal durability
- Closed impeller design ensuring efficient and stable hydraulic flow control
- Single-phase motor with built-in overload protection for operational safety
- TEFC motor enclosure with IP55 protection against environmental exposure
- Class F insulation system supporting continuous thermal operation
- Stainless steel hydraulic components for corrosion resistance and longevity
- Sealed ball bearing system for smooth rotation and reduced maintenance
- Compact close-coupled construction enabling efficient installation
SPECIFICATIONS
| Max Flow | 180 L/Min |
| Max Head | 20.5 m |
| Power | 0.55 kW / 240v |
| Rated Current | 4.6 Amps |
| Suitable For | Heating Systems |
| Body Material | 304 Stainless Steel |
| Liquid Temperature | Maximum 110°C |
| Inlet Size | 32 mm |
| Outlet Size | 25 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What flow capacity supports heated circulation systems?
Up to 180 L/Min is delivered by the CDXM_120_07_HT for heated clean-water circulation where steady volume movement is required. for thermal distribution circuits
Which thermal applications suit this pump configuration?
Heating systems thermal loops and controlled circulation networks can use the CDXM 120 07 HT for clean water under elevated temperature conditions.
What liquid temperature limit applies to this version?
A Carbon/Ceramic/Viton seal with Viton O-rings allows the CDXM-120-07-HT to operate with liquid temperatures reaching 110°C during continuous service. during normal elevated-temperature operation
What maximum head is stated for delivery?
The CDXM/120/07/HT provides a maximum head of 20.5 m for thermal circulation systems requiring stable discharge pressure at the stated flow.
Which electrical configuration protects the motor during operation?
A single-phase TEFC motor with built-in overload protection drives the CDXM12007HT while its IP55 enclosure and Class F insulation support reliable operation.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us