Grundfos MAGNA1 40-80 F Cast Iron Variable Speed Circulator Pump for Cooling Systems with Composite Impeller
SKU: 99221303

Grundfos MAGNA1 40-80 F Cast Iron Variable Speed Circulator Pump for Cooling Systems with Composite Impeller

$2,792.24 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
191 L/Min
Max Head
8 m
Power
0.19 kW / 240v
Ideal Use
Flanged AC Surfaces and Mixing Loops

Product Overview

Combining 40 mm flanged connections with high-flow variable speed regulation, the Grundfos MAGNA1 40-80 F circulator pump serves secondary chiller loops, commercial heating headers, and plate heat exchangers. Its internal inverter continuously balances pump output against circuit valve modulation.

A heavy EN-GJL-200 cast iron pump body with a 220 mm face-to-face length houses a precision composite impeller and maintenance-free canned rotor. Built for 10 bar working pressure, it accommodates fluid temperatures from -10°C to 110°C, with a total net weight of 16.3 kg.

The 1 x 230-240 V 50/60 Hz permanent magnet motor has a maximum power input (P1) of 17 W to 267 W while electrical input power (P1) draws between 17 W and 267 W with a maximum current of 1.18 A. Hydraulic output produces a calculated flow rate of 11.44 m³/h (191 L/Min) against a maximum head of 5.008 m through DN 40 DIN flanged connections.

Nine selectable control settings include proportional pressure, constant pressure, and fixed constant curve speeds. The unit achieves an Energy Efficiency Index (EEI) of 0.19, features Class F insulation with an IPX4D enclosure, and includes digital run/stop and fault relay terminals.

FEATURES

  • Flow capacity of 191 L/Min and 5.008 m of head serve demanding commercial HVAC loops
  • High-efficiency ECM motor technology delivers a low EEI rating of 0.19
  • Power consumption automatically varies from 17 W to 267 W based on thermal load
  • Cast iron EN-GJL-200 pump casing engineered for 10 bar maximum system pressure
  • Composite impeller provides longevity in closed-loop water and glycol mixtures
  • Digital start/stop input and fault alarm relay output serve building control systems
  • Standard 220 mm port-to-port dimension with DN 40 PN 6/10 flange holes
SPECIFICATIONS
Max Flow191 L/Min
Max Head8 m
Power0.19 kW / 240v
Rated Current1.18 Amps
Suitable ForFlanged AC Surfaces and Mixing Loops
Body MaterialCast Iron
Liquid Temperature'-10°C to 110°C
Inlet Size40 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Quick Guide Download

Chilled water distribution lines feeding air conditioning coils select The Grundfos MAGNA1 40-80 F for steady coolant transfer. Pre-fitted insulating shells prevent thermal energy losses and keep surrounding mechanical spaces clean and dry.

  • Chilled Water Loops
  • Air Conditioning Coils
  • Office Buildings
  • Cooling Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Quick Guide
Download
What motor power rating and running current power this pump?

Under full load conditions, the motor in the Grundfos MAGNA1 40-80 F delivers 0.19 kW on a 240v line drawing 1.18 Amps.

How is this pump mounted for quick inspection and servicing?

Mechanical mounting for the MAGNA1 40-80 F is configured around a standard standard connection for straightforward pit alignment.

What maximum vertical elevation head can this pump achieve?

Fluid elevation through vertical risers reaches up to 8 m with the MAGNA1-40-80-F under standard duty points.

How much water volume can this pump displace through its outlet?

Discharge throughput on the MAGNA1 40 80 F reaches a maximum flow rate of approximately 191 L/Min under standard operating conditions.

What materials protect the wetted parts against aggressive chemical attack?

Wetted components on the MAGNA1/40/80/F are crafted from high-grade Cast Iron to maintain physical integrity and resist abrasive wear.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed