With a 50 mm nominal bore, the Grundfos MAGNA1 50-60 F circulator pump delivers energy-efficient variable circulation for commercial primary boiler loops, secondary cooling headers, and large air handler coils. Its integrated frequency converter automatically adjusts motor rpm based on system valve movement.
A 240 mm port-to-port casing made from EN-GJL-200 cast iron houses a composite impeller, stainless rotor cladding, and maintenance-free canned rotor motor. Built for 10 bar working pressure, it handles circulating temperatures between -10°C and 110°C, with a total net weight of 17.4 kg.
The single-phase 230-240 V ECM motor has a maximum power input (P1) of 21 W to 252 W with electrical power input (P1) operating from 21 W up to a peak of 252 W at 1.15 A maximum current. Output metrics achieve a flow rate of 14.74 m³/h (246 L/Min) against a maximum head of 3.748 m across DN 50 DIN flanged pipe ports.
Nine selectable control modes cover proportional pressure, constant pressure, and fixed speed curves for straightforward hydronic balancing. Ingress protection is certified to IPX4D with Class F insulation, an EEI of 0.19, and an integrated fault signal relay.
FEATURES
- DN 50 flanged casing provides 246 L/Min maximum flow capacity for central plant headers
- Permanent magnet motor with integrated VFD achieves an EEI rating of 0.19
- Nine control modes adapt hydraulic output for radiator, underfloor, and constant flow
- Power consumption self-adjusts between 21 W and 252 W based on thermal demand
- Cast iron EN-GJL-200 housing built for 10 bar maximum operational pressure
- Composite impeller provides chemical corrosion resistance in hydronic loops
- Built-in fault relay contact and external digital run input for BMS interface
SPECIFICATIONS
| Max Flow | 246 L/Min |
| Max Head | 6 m |
| Power | 0.18 kW / 240v |
| Rated Current | 1.15 Amps |
| Suitable For | Flanged Heating Surfaces and AC Surfaces |
| Body Material | Cast Iron |
| Liquid Temperature | '-10°C to 110°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What kind of power supply does this pump require to run?
Electrical power for the Grundfos MAGNA1 50-60 F requires a 240v single-phase connection, driving an efficient 0.18 kW motor that draws 1.15 Amps.
How deep can this pump be installed underwater in a wet well?
Liquid operating limits establish that the MAGNA1 50-60 F accommodates temperatures -10°C to 110°C during standard duties.
What maximum vertical water column can this pump maintain?
Dynamic lift generated by the MAGNA1-50-60-F reaches a maximum elevation head of approximately 6 m across discharge lines.
What discharge flow rate does this pump maintain during peak operation?
Displacing fluid into connected headers, the MAGNA1 50 60 F sustains up to 246 L/Min of volumetric throughput.
What mounting system enables fast installation and retrieval of this pump?
Installation of the MAGNA1/50/60/F is streamlined using a standard standard connection, enabling fast docking onto existing discharge lines.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us