Grundfos UPS 40-180 F Cast Iron 415V Three Speed Circulator Pump with Stainless Steel Impeller
SKU: 96401979

Grundfos UPS 40-180 F Cast Iron 415V Three Speed Circulator Pump with Stainless Steel Impeller

$2,030.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
200 L/Min
Max Head
18 m
Power
0.77 kW / 415v
Ideal Use
High Rise Heating Circulation

Product Overview

Delivering high head performance in a compact 40 mm bore, the Grundfos UPS 40-180 F 415V circulator pump targets demanding high-rise heating risers and central cooling circuits. It provides the pressure necessary to circulate thermal water across multiple building levels and high-loss coils.

The casing is cast from EN-GJL-250 iron with a 250 mm port-to-port dimension, housing an EN 1.4301 stainless steel impeller, stainless rotor can, and bearing plate. Rated for 10 bar operating pressure, the assembly withstands liquid temperatures from -10°C to 120°C and weighs 21.3 kg.

Running on 3 x 400-415 V 50 Hz power, the motor has a maximum power input (P1) of 770 W at 1.3 A at maximum speed, with three selectable speed steps. Peak performance yields a maximum head of 18 m and a flow rate of 12.01 m³/h (200 L/Min) through DN 40 DIN flanged ports.

Fluid-lubricated ceramic radial bearings and a carbon axial bearing deliver low-vibration operation without mechanical seal degradation. The motor enclosure provides IPX4D ingress protection with Class H insulation and integral thermal switch contacts.

FEATURES

  • Generates 18 m maximum head for multi-floor commercial riser circulation
  • Three-phase 400-415 V operation provides low run current and balanced load
  • Three switchable speed steps facilitate accurate system commissioning
  • Cast iron EN-GJL-250 housing engineered for 10 bar maximum system pressure
  • Stainless steel AISI 304 impeller built for continuous high-pressure duty
  • Sealless canned rotor removes external seal replacement and leak paths
  • DN 40 flange mounting aligns with standard EN 1092-2 PN 6/10 pipework
SPECIFICATIONS
Max Flow200 L/Min
Max Head18 m
Power0.77 kW / 415v
Rated Current1.3 Amps
Suitable ForHigh Rise Heating Circulation
Body MaterialCast Iron
Liquid Temperature'-10°C to 120°C
Inlet Size40 mm
Outlet Size40 mm
Warranty24 Months
Documents
Specification Datasheet Download
Data Booklet Download
Quick Guide Download

High-resistance heating distribution manifolds requiring intense circulating pressure deploy the Grundfos UPS 40-180 F for reliable fluid transit. Heavy three-phase windings provide robust starting torque, overcoming initial system friction even after long summer shutdowns.

  • Distribution Manifolds
  • High Resistance Loops
  • Three Phase Skids
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Data Booklet
Download
Quick Guide
Download
What kind of power supply does this pump require to run?

Electrical power for the Grundfos UPS 40-180 F requires a 415 V connection, driving an efficient 0.77 kW motor that draws 1.3 Amps.

What size discharge flange or connection is fitted to this pump?

Connecting via a standard standard connection, the UPS 40-180 F aligns cleanly with system plumbing headers.

What maximum vertical water column can this pump maintain?

Dynamic lift generated by the UPS-40-180-F reaches a maximum elevation head of approximately 18 m across discharge lines.

What discharge flow rate does this pump maintain during peak operation?

Displacing fluid into connected headers, the UPS 40 180 F sustains up to 200 L/Min through a DN 40 connection of volumetric throughput.

What metallurgy is selected for the pump body to resist abrasive wear?

Durable Cast Iron construction gives the UPS/40/180/F exceptional structural strength and long-term protection against corrosive fluids.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed