Grundfos S2.110.200.1150.4.70M.S.416 Cast Iron 4-Pole Sewage Pump for Municipal Use with 2-Channel Impeller
SKU: 96810598

Grundfos S2.110.200.1150.4.70M.S.416 Cast Iron 4-Pole Sewage Pump for Municipal Use with 2-Channel Impeller

$68,187.53 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
2 Year Warranty
Peace of Mind
Max Flow
20160 L/Min
Max Head
66 m
Power
115 kW / 415v
Ideal Use
Municipal Sewage

Product Overview

Highlighting extended continuous circulation capacities, this pump is natively designed for handling wastewater, process water, unscreened raw sewage, municipal, domestic and industrial applications. The S2.110.200.1150.4.70M.S.416.G.N.D.513GPA unit is strictly suitable for submerged physical installation setups utilizing the active 96641489 auto coupling interface connection base to establish deep continuous fluid transfer capabilities.

Constructed from solid Cast iron EN 1561 EN-GJL-250, the physical outer housing surrounds central dynamic components. The 2-channel impeller, measuring exactly 417 mm in overall diameter, effectively processes suspended physical solids up to 110 mm in size. The internal core motor casing is manufactured from Cast iron EN 1561 EN-GJL-250. The mechanical unit weighs 1090 kg and operates strictly in Newtonian liquids up to 40°C.

The 115 kW electrical motor works on a three-phase 415v continuous power supply, operating with a designated steady continuous current of 203 Amps. The heavy industrial unit achieves a maximum head of 66 meters and a maximum flow volume of 20160 L/Min running directly through a DN 200 mm discharge outlet. The continuous operating power input P1 is specified directly at 122 kW, running alongside an electrical starting current rated exactly at 1380 Amps.

System thermal safety is strictly provided by Class F internal motor insulation combined with a rated IP68 physical enclosure parameter. The extensive hardware fully supports continuous vertical physical installation depths reaching up to 20 meters. Primary SIC mechanical seals and secondary SIC-CARBON shaft seals precisely provide constant internal fluid containment. The operational architecture incorporates a 4-pole motor matched with a Y/D starting mechanism.

Features

  • Features lifting height class M standard dimension specification for operation
  • Integrates internal physical moisture sensors explicitly for continuous fluid system evaluation
  • Includes core hardware thermistors designed for active thermal response observations
  • Utilizes S1BN8-F specification active power cable measuring precisely 15 meters
  • Operates actively with a continuous mechanical baseline speed of 1475 revolutions per minute
  • Accommodates a standard maximum of 15 electrical motor starts per operational hour

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow20160 L/Min
Max Head66 m
Power115 kW / 415v
Rated Current203 Amps
Suitable ForMunicipal Sewage
Body MaterialCast Iron
Liquid TemperatureMaximum 40°C
Outlet Size200 mm
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Across regional municipal sewage collection mains, The Grundfos S2.110.200.1150.4.70M.S.416 maintains steady fluid velocity through wide subterranean sewer pipes. The heavy cast iron housing provides long-term structural durability within demanding wastewater sumps.

  • Sewage Collection Mains
  • Subterranean Sewer Pipes
  • Municipal Treatment Intakes

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
What is the maximum water flow rate and head pressure of this pump?

Achieving strong system delivery, the Grundfos S2.110.200.1150.4.70M.S.416 develops a maximum flow rate of 20160 L/Min and a maximum dynamic head of 4.70M across its operating curve.

What total dynamic head can this pump overcome in vertical pipework?

Dynamic lift generated by the S2.110.200.1150.4.70M.S.416 reaches a maximum elevation head of approximately 4.70M across discharge lines.

What electrical connection and motor power run this pump?

Connecting across 415 V three-phase lines, the S2-110-200-1150-4-70M-S-416 draws approximately 203 Amps with an efficient 115 kW motor.

How high can this pump push fluid through discharge risers?

Vertical elevation capability on the S2 110 200 1150 4 70M S 416 reaches a maximum dynamic head of approximately 70M under rated conditions.

How much vertical head pressure can this pump generate?

To overcome vertical elevation resistance, the S2/110/200/1150/4/70M/S/416 develops a maximum pumping head of approximately 70M.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed