Large heating networks combine both high resistance and high volume, requiring a pump that can deliver both. The Grundfos UPS 32-100 meets that demand by pairing the widest bore in the cast iron UPS range with its tallest head rating, suited to commercial risers, district-style heating loops, and extensive multi-zone residential systems.
At full speed the pump delivers approx. 225 L/Min with a maximum head up to 10 m, with three speed settings stepping power from 280 W to 345 W and current reaching 1.52 A on a 1 x 240 V supply. The 2 inch connection reduces flow velocity and associated resistance compared with the narrower-bore UPS 25-100 at equivalent volumes.
Canned rotor construction runs through the model, with bearings lubricated by the circulating heating water rather than a mechanical seal. Liquid temperature tolerance extends from -25°C to 110°C, and the cast iron housing is intended for closed-loop heating rather than potable circuits.
Class H insulation and an IPX4D enclosure reflect the higher thermal and ingress protection demands of running at 345 W continuously. At 180 mm port-to-port, the pump matches the physical footprint of the 1 1/2 inch UPS 25-100, allowing bore size to be increased during a system upgrade without altering pump spacing.
FEATURES
- Larger 2 inch connections reduce flow velocity and associated resistance at equivalent volumes
- Head rating of up to 10 m provides pressure capability for commercial risers, district-style heating loops, and extensive multi-zone residential systems
- Three-speed selector permits commissioning engineers to match output to actual system requirements
- Canned rotor design with self-lubricating bearings eliminates the mechanical shaft seal
- Class H insulation (180°C) supports continuous operation at full 345 W load
- IPX4D enclosure rating provides ingress protection against splashing water and dust
- Cast iron housing specified for closed-loop heating applications where potable water approval is not required
- 180 mm port-to-port body dimension matches the footprint of the 1 1/2 inch UPS 25-100
SPECIFICATIONS
| Max Flow | 225 L/Min |
| Max Head | 10 m |
| Power | 0.35 kW / 240v |
| Rated Current | 1.52 Amps |
| Suitable For | Commercial Heating Network |
| Body Material | Cast Iron |
| Liquid Temperature | -25°C to 110°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
How high can this pump push fluid through discharge risers?
Vertical elevation capability on the Grundfos UPS 32-100 reaches a maximum dynamic head of approximately up to 10 m under rated conditions.
What is the maximum flow capacity of this pump per minute?
Fluid evacuation capacity for the UPS 32-100 peaks at approximately 225 L/Min, providing dependable high-volume drainage.
What metallurgy is selected for the pump body to resist abrasive wear?
Manufactured with quality materials, the UPS-32-100 incorporates Cast Iron for dependable longevity and resistance to fluid erosion.
What voltage supply and motor power does this pump need?
Under full load conditions, the motor in the UPS 32 100 delivers 0.35 kW on a 240 V line drawing 1.52 Amps.
What liquid temperatures can this pump tolerate during standard operation?
Tested for thermal durability, the UPS/32/100 tolerates working fluid temperatures -25°C to 110°C.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us