Lowara CO 500/15 Stainless Steel Back Pull-Out Centrifugal Pump for Industrial Transfer with Open Impeller
SKU: CO500/15

Lowara CO 500/15 Stainless Steel Back Pull-Out Centrifugal Pump for Industrial Transfer with Open Impeller

$2,505.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
650 L/Min
Max Head
12.7 m
Power
1.84 kW / 415v
Ideal Use
Industrial Water Circulation

Product Overview

This Lowara CO series centrifugal pump is engineered for demanding industrial environments where consistent clean or slightly contaminated water movement is required. Ideal for cooling systems and process fluid handling, this unit provides reliability for facilities requiring non-stop circulation. By utilizing high-grade materials, the pump effectively manages fluids in civil or industrial setups where structural integrity is a primary operational requirement for maintaining uptime.

Hydraulic capacity for this configuration reaches a Max Head 12.7 m and a Max Flow 650 L/Min. Powering this movement is a 1.84 kW / 415v motor designed to sustain consistent performance during heavy-duty cycles. The unit features 50mm inlet and 40mm outlet ports to accommodate high-volume fluid throughput while maintaining velocity control throughout the system architecture.

Construction relies on AISI 316L stainless steel for the hydraulic body and internal components, ensuring resistance to aggressive liquids. The motor is a TEFC asynchronous design providing external ventilation to keep operating temperatures stable. Internal geometry features an open configuration to allow the passage of suspended solids up to 20mm, preventing clogging and mechanical fatigue during standard operational conditions.

Installation is simplified through a horizontal close-coupled design that integrates easily into existing plumbing manifolds. The pump is protected against liquid ingress with an IP55 enclosure rating, making it suitable for damp installation environments. Safety is bolstered by the FKM elastomeric seals which provide chemical resistance across a broad temperature range of -10°C up to 110°C, supporting diverse process water applications.

Features:

  • Integrated AISI 316L stainless steel hydraulic body and casing
  • Suitable for handling suspended solids up to 20mm diameter
  • Asynchronous motor compliant with IE3 efficiency regulations
  • FKM elastomer seals for broad chemical and thermal resistance
  • IP55 rated enclosure for installation in variable environments
  • Close-coupled design for minimized footprint in plant rooms
SPECIFICATIONS
Max Flow650 L/Min
Max Head12.7 m
Power1.84 kW / 415v
Rated Current3.29 Amps
Suitable ForIndustrial Water Circulation
Body MaterialAISI 316L Stainless Steel
Liquid Temperature-10°C to +110°C
Inlet Size50 mm
Outlet Size40 mm
Warranty12 Months
Documents
Specification Datasheet Download
Operating Manual Download

High-volume process-water circuits with washing and cooling duties can use the Lowara CO 500/15 when suspended solids may occur. Its clog-resistant approach suits utility and cleaning systems requiring consistent circulation through demanding service conditions.

  • Process Water
  • Cooling Systems
  • Parts Washing
  • Solid Handling

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Operating Manual
Download
What maximum dynamic head does this open-impeller industrial circulation pump develop?

Circulating liquids with suspended particulates, the CO500/15 achieves a maximum dynamic head of approximately 16.0 m across its operating curve.

What peak flow volume can this open-impeller circulation pump deliver through its discharge outlet?

Open-impeller fluid transfer is powered by the CO500-15, discharging a maximum water flow rate of approximately 700 L/Min via Rp 2" (50 mm) suction and Rp 1-1/2" (40 mm) discharge ports.

How is this open-impeller circulation pump protected against abrasive particulate erosion and corrosion?

Suspended solids passage and corrosion defense rely on alloy metallurgy materials in the CO 500 15, featuring AISI 316L stainless steel casing and open impeller, with ceramic/carbon/FPM mechanical seal capable of managing suspended solids up to 20 mm in diameter.

What electrical power and three-phase supply voltage are needed to drive this open-impeller circulation pump?

Supplying electricity to the CO_500_15 requires a 1.5 kW three-phase motor connection on 380–415 V, 50 Hz, three-phase pulling 3.29 A, engineered with IP55 dust and water spray protection, Class F insulation.

Where is equipment room installation recommended for this open-impeller pump on a horizontal base?

Surface floor mounting on a horizontal rigid foundation base is recommended for the CO500/15, installed with an integrated layout and proper floor drainage.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed