Grundfos UPS 50-60/2 F Cast Iron 415V Three Speed Circulator Pump with Stainless Steel Impeller
SKU: 96402055

Grundfos UPS 50-60/2 F Cast Iron 415V Three Speed Circulator Pump with Stainless Steel Impeller

$2,335.58 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
258 L/Min
Max Head
6 m
Power
0.2 kW / 415v
Ideal Use
Secondary Heating and Cooling Circuits

Product Overview

Sized with a 50 mm nominal bore, the Grundfos UPS 50-60/2 F 415V circulator pump addresses moderate-flow secondary heating circuits and commercial chilled water systems. It installs into central plant distribution headers where low head loss and steady circulation are required.

Constructed with an EN-GJL-250 cast iron pump housing measuring 280 mm port-to-port, the unit incorporates an EN 1.4301 stainless steel impeller and aluminium stator body. It is rated for 10 bar working pressure and liquid temperatures from -10°C to 120°C, with a net mass of 20.6 kg.

The 3-phase 400-415 V 50 Hz motor has a maximum power input (P1) of 360 W with a peak electrical power input (P1) of 360 W and draws 0.74 A on speed 3, stepping down to 230 W on lower settings. Flow capacity reaches 15.5 m³/h (258 L/Min) with a maximum head of 4.8 m across DN 50 DIN flanged terminations.

The canned rotor configuration utilizes ceramic radial bearings and a carbon thrust bearing bathed in the pumped fluid, removing external seal maintenance. The terminal box provides IPX4D ingress protection and links internal thermal protection switches to safety disconnects.

FEATURES

  • DN 50 flanged connection provides 258 L/Min maximum flow capacity for secondary headers
  • Three manual operational speeds provide flexibility during hydronic balancing
  • Three-phase 400-415 V motor creates balanced load on commercial power supplies
  • Cast iron EN-GJL-250 housing rated for 10 bar maximum operational pressure
  • Stainless steel AISI 304 impeller provides chemical durability in treated water
  • Canned rotor motor design operates without gland packing or mechanical seals
  • Standard 280 mm port-to-port dimension conforms to commercial DIN flange spacing
SPECIFICATIONS
Max Flow258 L/Min
Max Head6 m
Power0.2 kW / 415v
Rated Current0.74 Amps
Suitable ForSecondary Heating and Cooling Circuits
Body MaterialCast Iron
Liquid Temperature'-10°C to 120°C
Inlet Size50 mm
Outlet Size50 mm
Warranty24 Months
Documents
Specification Datasheet Download
Data Booklet Download
Quick Guide Download

Low-pressure hydronic distribution loops in community buildings rely on the Grundfos UPS 50-60/2 F for high volumetric water transit. The large flanged volute moves heavy fluid volumes smoothly, keeping large radiant panels evenly heated.

  • Community Buildings
  • Low Pressure Loops
  • Flanged Volutes
  • Radiant Panels

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Data Booklet
Download
Quick Guide
Download
What are the maximum installation depth and liquid temperature boundaries?

Liquid operating limits establish that the Grundfos UPS 50-60/2 F accommodates temperatures -10°C to 120°C during standard duties.

How high can this pump lift water vertically?

Dynamic lift generated by the UPS 50-60/2 F reaches a maximum elevation head of approximately 6 m across discharge lines.

What maximum flow rate does this pump achieve during heavy influx?

Displacing fluid into connected headers, the UPS-50-60-2-F sustains up to 258 L/Min through a DN 50 connection of volumetric throughput.

What materials are used to construct the pump casing and impeller?

Durable Cast Iron construction gives the UPS 50 60 2 F exceptional structural strength and long-term protection against corrosive fluids.

How much power does the motor consume during standard operation?

Powered by a dedicated 0.2 kW motor, the UPS/50/60/2/F connects to 415 V mains power with a rated current draw of 0.74 Amps.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed