Product Overview
Flooded room drainage and the extraction of water from reservoirs are handled by the Calpeda GQR 10-12. This three-phase submersible unit is engineered for handling clean water containing suspended solids up to 10 mm in diameter. It is particularly effective for domestic drainage, rainwater collection, and irrigation pits with a maximum liquid temperature of 35°C during continuous duty service.
Powered by a 0.55 kW three-phase 415v supply, this model reaches a maximum head of 11.6 m and a maximum flow rate of 350 L/min. Drawing a rated current of 1.4 Amps, the motor remains cooled by the pumped water passing through the external jacket. This thermal management system supports safe operation during extended run cycles even when the motor is only partially submerged.
An open single impeller design manufactured from cast iron allows for efficient flow behavior when managing clean water with small suspended particles. The vertical delivery port configuration assists in compact installations, while the integrated AISI 304 filter restricts the entry of oversized debris. The unit is designed for permanent installation in the standing position with a minimum immersion depth of 205 mm.
Construction consists of a cast iron GJL 200 pump casing and impeller for enhanced structural durability. Motor protection is provided by a double mechanical shaft seal with an interposed oil chamber housing oil for food and pharmaceutical machinery. The induction motor features a triple impregnation humidity-proof dry winding and is rated for immersion depths up to 5 meters.
FEATURES
- Manufactured with a cast iron pump casing and impeller for structural durability in high-demand systems.
- Double mechanical shaft seal with an interposed oil chamber protects against dry-running and water ingress.
- Mechanical shaft seal lubrication is provided by specialized oil safe for food and pharmaceutical machinery.
- Internal cooling is achieved by the pumped liquid flowing between the motor jacket and the external jacket.
- Open cast iron impeller design handles clean water containing suspended solids up to 10 mm in diameter.
- The three-phase 415v 2-pole induction motor is designed for reliable service in continuous duty applications.
- Motor reliability is supported by a triple impregnation humidity-proof dry winding constructed to EN 60034-1.
- Certified IP X8 protection rating facilitates continuous duty immersion at depths reaching up to 5 meters.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What liquid temperature is permitted during continuous drainage?
Clean water up to 35°C can be handled continuously by GQR_10_12 during drainage from collection pits and rainwater reservoirs.
Which impeller construction handles suspended particles in the water?
The single open cast-iron impeller fitted to GQR 10-12 moves clean water carrying particles up to 10 mm through the hydraulic section.
What electrical supply and motor rating does it use?
Powering GQR-10-12 is a 0.55 kW three-phase 415V motor, drawing 1.4 Amps during continuous drainage from collection pits and tanks.
How deep must the pump remain submerged during operation?
Permanent standing installation requires at least 205 mm immersion for GQR/10/12, while IPX8 protection permits immersion up to 5 metres.
Which materials form the pump casing and impeller?
Structural parts of GQR 10 12 use GJL 200 cast iron for the casing and impeller, with an AISI 304 filter screening incoming debris.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us