Max Flow
1700 L/Min
Max Head
8.2 m
Power
2.2 kW / 415v
Ideal Use
Raw Sewage Pumping

Product Overview

Suitable applications for this vertical unit include raw sewage pumping, waste water, and storm water transfer. It handles liquid temperatures reaching 40°C and is IP68 rated for submerged operation. The pump is designed for manual operation in civil or industrial collection pits where solids-laden fluids must be moved vertically to discharge mains.

Operating with a 2.2 kW motor, this manual three-phase unit reaches flow rates up to 1700 L/Min and a total head of 8.2 m. Drawing a rated current of 5.2 Amps on a 415v supply, the unit is equipped with 10 m of submersible power cable. The air-filled dry submersible 4-pole motor is designed for direct-on-line (DOL) starting and operates at a synchronous speed of 1500 rpm.

The enclosed single-channel impeller arrangement is designed for non-clog operation when handling fluids containing suspended solids. This hydraulic system permits the passage of foreign matter up to 76 mm in diameter. Fluid is moved through an 80 mm vertical delivery port connected to the included discharge elbow with companion flange.

Materials of construction feature a cast iron pump casing, motor frame, and impeller paired with an AISI 403 stainless steel shaft. Sealing is managed by a double mechanical seal in an intermediate oil chamber utilizing Silicon Carbide lower faces and Carbon/Ceramic upper faces. Fasteners are 304 stainless steel, and the motor incorporates an automatic thermal protector.

FEATURES

  • Enclosed single-channel non-clog impeller enables the handling of 76 mm solids.
  • Air-filled dry submersible 4-pole motor rated for continuous duty at 50Hz frequency.
  • Shaft sealing uses a double mechanical system isolated in an oil chamber for motor protection.
  • Utilizes Silicon Carbide lower seal faces for wear resistance in abrasive wastewater.
  • Includes an 80 mm screwed discharge elbow with companion flange, gaskets, and bolts.
  • AISI 403 stainless steel shaft and 304 fasteners provide resistance to environmental corrosion.
  • Intermediate oil chamber filled with turbine oil (SAE 10W/20W) for seal lubrication.
  • Double-row lower bearings provide mechanical support for the rotating assembly.
SPECIFICATIONS
Max Flow1700 L/Min
Max Head8.2 m
Power2.2 kW / 415v
Rated Current5.2 Amps
Suitable ForRaw Sewage Pumping
Body MaterialCast Iron
Liquid TemperatureMaximum 40°C
Outlet Size80 mm
Warranty12 Months
Documents
Product Brochure Download
D Series Product Brochure Download
Specification DataSheet Download
Technical DataSheet Download

Solids-laden wastewater requires pumping equipment capable of passing larger foreign matter without frequent blockage. The Ebara 80 DML 52.2 uses an enclosed single-channel impeller for moving raw sewage and stormwater from civil and industrial collection pits in submerged installations.

  • Raw Sewage Transfer
  • Stormwater Drainage
  • Industrial Wastewater Pumping
  • Collection Pit Drainage

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
D Series Product Brochure
Download
Specification DataSheet
Download
Technical DataSheet
Download
Which wastewater applications suit this manual vertical pump?

Raw sewage and stormwater transfer suit 80_DML_52_2 for manual pumping from civil or industrial collection pits where gravity drainage is unavailable.

What maximum flow is available for sewage transfer?

High-volume sewage transfer can reach a maximum flow of 1700 L/Min through 80 DML 52 2 from collection pits.

How does the impeller handle large suspended solids?

The enclosed single-channel impeller on 80-DML-52-2 passes foreign matter up to 76 mm during non-clog sewage transfer from collection pits.

What starting method and motor supply are specified?

With 2.2 kW output, 80/DML/52/2 uses 415 V three-phase DOL starting and draws 5.2 Amps with a 10 m cable.

What maximum head supports vertical drainage discharge?

Manual discharge from collection pits can use the maximum head of 8.2 m provided by 80DML522 for vertical wastewater transfer.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed