Max Flow
160 L/Min
Max Head
12 m
Power
0.4 kW / 240v
Ideal Use
Commercial Systems

Product Overview

High capacity commercial secondary tap hot water circulation with up to 12 m head requirements, domestic water piping loops, solar primary circuits, and radiator loops are effectively handled by the Lowara TLCHN 25-12L. This wet rotor circulator pump delivers maximum performance for the most demanding commercial sanitary water applications.

Three speed manual selection provides comprehensive performance flexibility. Speed 1 at 285 W draws 1.36 A, Speed 2 at 372 W draws 1.69 A, and Speed 3 at 400 W draws 1.73 A on 240 V single-phase supply. Maximum head reaches 12 m with flow up to 160 L/Min at rated conditions.

The high performance motor is configured with ceramic axial and radial bearings lubricated by the pumped liquid. The stainless steel pump body provides corrosion resistance, while the composite impeller and ceramic wear ring deliver efficient, long-lasting hydraulic performance. The wet rotor design ensures quiet operation.

Installation is suitable for horizontal or vertical piping with motor axis horizontal. Threaded connections are available in 1"1/4 and 1"1/2 sizes. Liquid temperature capability ranges from +2°C to +110°C with recommended maximum of 65°C. Maximum operating pressure is 10 bar PN10 with IP44 protection class.

FEATURES

  • Stainless steel pump body for corrosion resistance in commercial systems
  • Maximum performance motor configuration for demanding applications
  • Three speed manual selector for operational flexibility
  • Ceramic bearings and wear ring for extended service life
  • Composite impeller for hydraulic efficiency
  • Wet rotor design with pumped liquid lubrication
  • Integrated terminal box for simplified electrical connection
SPECIFICATIONS
Max Flow160 L/Min
Max Head12 m
Power0.4 kW / 240v
Rated Current1.73 Amps
Suitable ForCommercial Systems
Body MaterialStainless Steel
Liquid Temperature+2°C to +110°C
Inlet Size40 mm
Outlet Size40 mm
Warranty12 Months
Documents
Specification Datasheet Download
Manual Download

Commercial secondary tap hot water loops needing up to 12 m of head are supported by the Lowara TLCHN 25-12L, featuring a stainless steel casing and composite impellers to move up to 160 L/Min.

  • Commercial Hot Water
  • Hot Water Recirculation
  • Solar Heating

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Manual
Download
What is the highest head capacity available from this commercial circulator?

Generating the highest lift in its class, the TLCHN 25-12L produces up to 12 m of head with a flow capacity of 160 L/Min.

How much current does this unit draw at its highest speed setting?

At Speed 3 on a 240 V single-phase supply, the TLCHN-25-12L draws 1.73 A with a total power consumption of 400 W.

In what pipe positions can this secondary hot water pump be installed?

Pipework can run horizontally or vertically as long as the motor shaft of the TLCHN 25 12L remains horizontal.

What material construction makes this pump suitable for potable water?

A corrosion-resistant stainless steel casing and composite impeller make the TLCHN_25_12L completely safe for sanitary water.

What is the maximum working pressure rating for this heavy-duty circulator?

Built to PN10 standards, the TLCHN 25-12L safely manages system operating pressures up to 10 bar.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed