Grundfos DDA 60-10 PVDF AR Control Digital Dosing Pump for Chemical Dosing
SKU: 99245401

Grundfos DDA 60-10 PVDF AR Control Digital Dosing Pump for Chemical Dosing

$8,605.58 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1 L/Min
Max Head
100 m
Power
0.062 kW / 240v
Ideal Use
High-Volume Chemical Dosing

Product Overview

Large-scale industrial transfer demands a configuration that provides high-capacity dosing and control and status feedback. This Smart Digital XL unit is intended for properties and plants that require the flexibility of manual adjustment combined with digital pulse and alarm relay outputs for synchronised chemical injection.

The unit is driven by a 62 W motor operating on 240v, delivering a maximum flow rate of 60.0 L/h against a 10 bar maximum backpressure. It utilises an 800:1 turn-down ratio, allowing for consistent volumetric accuracy across a broad range of settings down to a minimum of 0.075 L/h to match site specific chemical needs.

The hydraulic design features stepper motor technology that ensures smooth and continuous dosing. The AR control variant includes pulse input, analog 0/4-20mA control, and two potential-free output relays, ensuring the unit can be fully synchronised with complex site process automation.

Mechanical integrity is provided by a PVDF dosing head and durable PTFE gaskets paired with ceramic ball valves. Housed in a robust IP65 enclosure, it handles liquid temperatures to 50°C, includes high-capacity U3 connection packs for throughput, and features two potential-free output relays for alarm signalling or integration with external control systems.

FEATURES

  • AR control variant with manual, pulse and analog 0/4-20mA operation and potential-free alarm relays.
  • Low-level and tank empty signal inputs for system protection.
  • 800:1 turn-down range from 60.0 L/h down to 0.075 L/h for precise dosing.
  • Stepper motor drive provides smooth and continuous dosing.
  • PVDF pump head, PTFE gaskets and ceramic ball valves for aggressive chemical resistance.
  • IP65 rated enclosure protects internal electronics in industrial environments.
  • High-capacity U3 connection packs for maximum throughput.
  • Two potential-free output relays for alarm signalling or integration with external control systems.
SPECIFICATIONS
Max Flow1 L/Min
Max Head100 m
Power0.062 kW / 240v
Suitable ForHigh-Volume Chemical Dosing
Body MaterialPVDF
Liquid TemperatureMaximum 50°C
Inlet Size19, 20, 25, 27 mm
Outlet Size19, 20, 25, 27 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Quick Guide Download

Heavy manufacturing facilities dispensing caustic neutralization reagents utilize the Grundfos DDA 60-10 for reliable PLC-automated dosing. Flexible bus communication cards allow plant control rooms to monitor stroke rates and operating hours remotely.

  • Manufacturing Plants
  • Caustic Neutralization
  • Chemical Storage
  • Automation Skids

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Quick Guide
Download
What working pressure in bar and chemical liquid temperature threshold apply to this unit?

Chemical feed parameters certify that the DDA 60-10 operates reliably at pressures up to 10 bar in temperatures up to 50 °C.

How much dynamic head lift can this industrial chemical injection unit provide?

Dynamic head performance certified for the Grundfos DDA 60-10 reaches a maximum elevation rating of approximately 100.0 m.

How much fluid flow volume in liters per minute does this chemical dosing assembly discharge?

Dispensing fluid accurately into treatment streams, the DDA-60-10 produces a maximum delivery flow volume of approximately 1.0 L/Min (60.0 L/h) through 19, 20, 25, 27 mm ports.

How are the wetted component material and internal structure construction protected from corrosion?

Fluid containment and chemical defense on the Grundfos DDA 60 10 are secured by PVDF wetted elements supporting demanding industrial duty.

What electrical supply voltage and motor kilowatt power energize this chemical dosing pump?

Power requirements for the DDA 60-10 AR-PVTC-F-31U3U3IG demand 240 V to drive an electric motor rated at 0.062 kW (62 W).

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed