Grundfos DDA 60-10 PVDF FlowControl Digital Dosing Pump for Water Treatment with AutoFlowAdapt
SKU: 99246435

Grundfos DDA 60-10 PVDF FlowControl Digital Dosing Pump for Water Treatment with AutoFlowAdapt

$10,869.05 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1 L/Min
Max Head
100 m
Power
0.062 kW / 240v
Ideal Use
Industrial Water Treatment

Product Overview

Bulk chemical handling and high-capacity water treatment duties require the increased hydraulic power of the Smart Digital XL series. This configuration is intended for industrial users who need to move significant dosing volumes with the same level of digital precision and monitoring found in standard units.

Powered by a 62 W motor, this system produces a maximum flow of 60 L/h against a 10 bar maximum operating pressure. It features an 800:1 turn-down ratio, providing the hydraulic strength required to manage large-scale chemical injection while maintaining the ability to scale down to a minimum flow of 0.075 L/h.

The system utilises advanced stepper motor technology to provide smooth and continuous dosing suitable for even viscous or degassing liquids. FlowControl continuously monitors the dosing process, while AutoFlowAdapt automatically compensates for changes in process pressure to maintain accurate dosing.

Structural integrity is provided by a PVDF dosing head and a durable PTFE diaphragm supported by ceramic ball valves. Connectivity is enhanced with communication functions available according to the selected control variant. The unit is rated for liquid temperatures up to 50°C and includes U3 connection packs for high-volume throughput.

FEATURES

  • FlowControl monitors the dosing process and detects abnormal operating conditions.
  • AutoFlowAdapt automatically compensates for changes in process pressure to maintain accurate dosing.
  • 800:1 turn-down ratio from 60 L/h down to 0.075 L/h for precise control.
  • Stepper motor technology provides smooth and continuous dosing.
  • PVDF pump head, PTFE diaphragm and ceramic ball valves for aggressive chemical resistance.
  • Communication functions available according to the selected control variant.
  • Integrated flow measurement for real-time dosing verification.
  • IP65 rated enclosure with U3 connection packs for high-volume throughput.
SPECIFICATIONS
Max Flow1 L/Min
Max Head100 m
Power0.062 kW / 240v
Suitable ForIndustrial Water Treatment
Body MaterialPVDF
Liquid TemperatureMaximum 50°C
Inlet Size19, 20, 25, 27 mm
Outlet Size19, 20, 25, 27 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Quick Guide Download

Regional water purification works handling massive potable volumes deploy the Grundfos DDA 60-10 for high-capacity, auto-regulating chemical dosing. Full internal flow measurement detects pressure changes instantly, maintaining consistent disinfectant concentrations without manual re-tuning.

  • Purification Works
  • Potable Mains
  • Chemical Skids
  • Municipal Water

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Quick Guide
Download
What peak delivery flow rate and discharge port sizing support chemical dosing?

Chemical transfer across processing loops relies on the DDA 60-10 discharging a peak delivery flow rate of approximately 1.0 L/Min (60 L/h) via 19, 20, 25, 27 mm fittings.

What alloy sensor components and wetted material construction resist disinfection corrosion?

Processing industrial reagents without leakage, the Grundfos DDA 60-10 combines PVDF wetted architecture with durable chemical gaskets.

What motor kilowatt power and electrical supply voltage feed this chemical dosing unit?

Electrical energization of the DDA-60-10 utilizes 240 V supplying an industrial drive rated at 0.062 kW (62 W).

What maximum operating pressure in bar and chemical liquid temperature apply during dosing?

Dosing service guidelines allow the Grundfos DDA 60 10 to operate at pressures up to 10 bar with chemical temperatures reaching up to 50 °C.

How high in vertical head elevation can this chemical dosing unit propel solutions?

Hydraulic pressure capability engineered into the DDA 60-10 FCM-PVTC-F-31U3U3IG establishes a maximum dynamic head of approximately 100.0 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed