Max Flow
468 L/Min
Max Head
23.53 m
Power
3 kW / 415v
Ideal Use
Cooling Tower Hydronic Systems

Product Overview

The NB 32-125/142 end-suction centrifugal pump incorporates a 3 kW electric drive motor connected to DN 50 suction and DN 32 discharge flanged piping joints. Designed for continuous building service duty, the unit handles clean fluid movement across commercial plant installations.

Hydraulic rating calculations confirm a flow capacity of 468 L/Min at a maximum head threshold of 23.53 m. The volute housing is constructed from cataphoresis treated cast iron. Rotor hydraulics feature a stainless steel impeller supported by bronze wear rings. Total net weight measures 57 kg.

Motor electrical configuration on the NB 32-125/142 pump requires a 415 V three-phase connection rated at 3 kW output power. Operating current measures 9.86 Amps at nominal speed. Liquid temperature ranges extend from -25°C to 120°C under 16 bar pressure. Connection is made via DN 50 inlet and DN 32 outlet flanges.

Motor security on the NB 32-125/142 end-suction pump features an IP55 rated housing, Class F thermal insulation, and PTC thermistor winding relays. The back-pull-out structural geometry permits technicians to remove the motor drive and rotor without dismantling connected suction or discharge pipe headers.

Features

  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow468 L/Min
Max Head23.53 m
Power3 kW / 415v
Rated Current10.3 Amps
Suitable ForCooling Tower Hydronic Systems
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size50 mm
Outlet Size32 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Boiler feed and primary plant loops depend on The Grundfos NB 32-125/142 for robust volumetric output across central headers. The induction drive generates strong hydraulic thrust, keeping facility distribution loops properly pressurized throughout winter.

  • Boiler Plant Loops
  • Central Headers
  • Primary Heating
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
Across facility central distribution headers, what peak flow capacity is certified on site?

Across facility central distribution headers, Grundfos NB 32-125/142 provides an operational throughput of approximately 468 L/Min.

Which durable alloys give this foot-mounted centrifugal unit its structural endurance?

Manufactured for rigid mechanical rooms, NB 32-125/142 pairs an EN-GJL-250 cast iron casing with a precision-cast bronze impeller.

Which motor kilowatt output, three phase electrical feed, and running current run this machine?

The high-torque induction drive in NB-32-125-142 provides 3 kW of mechanical power on a three-phase 415 V line pulling 10.3 Amps.

Supporting high-temperature boiler circuits, what liquid operating range is certified on site?

Safe fluid containment is maintained by NB 32 125 142 for process liquids spanning -25°C to 120°C under working pressures of 10 bar.

Through rigid end-suction manifolds, what maximum dynamic pressure height can be attained?

In commercial mechanical rooms, NB/32/125/142 provides a steady dynamic discharge lift of approximately 23.53 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed