Grundfos NB 32-200.1/205 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93208694

Grundfos NB 32-200.1/205 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller

$5,212.63 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
372 L/Min
Max Head
43.54 m
Power
5.5 kW / 415v
Ideal Use
Industrial Water Infrastructure

Product Overview

Operating with a 5.5 kW motor rating, the NB 32-200.1/205 end-suction centrifugal pump features end-suction axial inlet (DN 50) and top radial outlet (DN 32) connections. The pump is specified for district heating, commercial air conditioning loops, and industrial water distribution.

The pump's hydraulic assembly yields 372 L/Min rated flow volume and a maximum operational head of 43.54 m. Structural strength relies on an EN-GJL-250 cast iron casing with cataphoresis coating. Internal hydraulics feature a stainless steel impeller and BQQE shaft seal. Physical product weight equals 106 kg.

The NB 32-200.1/205 pump's 415 V three-phase drive motor delivers 5.5 kW power output while drawing 10.5 Amps operating current. The pump accommodates circulating fluid temperatures from -25°C to 120°C under working pressures up to 16 bar. Standardized DN 50 suction and DN 32 discharge ports facilitate line placement.

An IP55 enclosure rating protects motor components on the NB 32-200.1/205 unit, backed by Class F insulation and built-in PTC thermistor sensors. Scheduled maintenance routines utilize back-pull-out access, enabling motor drive and impeller removal while leaving volute casing flange joints intact.

Features

  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow372 L/Min
Max Head43.54 m
Power5.5 kW / 415v
Rated Current10.5 Amps
Suitable ForIndustrial Water Infrastructure
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size50 mm
Outlet Size32 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Central energy plant primary manifolds install The Grundfos NB 32-200.1/205 to drive high-temperature water through primary boiler headers. Robust drive engineering delivers mechanical power, maintaining steady circulation under peak winter operating loads.

  • Central Energy Plants
  • Primary Boiler Headers
  • High-Temperature Water
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
What surface protection and impeller materials are built into this heavy-duty end-suction unit?

Superior casing metallurgy in Grundfos NB 32-200.1/205 is established by an EN-GJL-250 cast iron volute alongside a durable stainless steel impeller.

How much electrical power does this base-mounted drive draw across incoming voltage and amps?

Site distribution networks must supply a three-phase 415 V feed to run the 5.5 kW motor of NB 32-200.1/205 at 10.5 Amps.

Discharging water into distribution headers, what thermal operating limits are certified on site?

Safe fluid circulation across -25°C to 120°C is provided by NB-32-200.1-205 with maximum system working pressure tolerance up to 10 bar.

Anchored to concrete inertia pads, what peak dynamic lift capability is certified on site?

Converting rotational torque into vertical thrust, NB 32 200.1 205 delivers a maximum dynamic head of approximately 43.54 m.

Discharging water into central distribution headers, what maximum flow rate is certified on site?

Discharging water into central distribution headers, NB/32/200.1/205 delivers a peak flow rate of approximately 372 L/Min.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us