Product Overview

Driven by a 3 kW electric motor, the NB 40-125/127 end-suction centrifugal pump features an axial suction port (DN 65) and a radial discharge port (DN 40). Specified for commercial HVAC circulation, district heating installations, and industrial process water distribution, the pump mounts securely onto floor inertia bases in mechanical plant rooms.

Hydraulic wet-end output delivers a rated flow volume of 750 L/Min with a maximum operational head limit of 16.09 m. The EN-GJL-250 cast iron casing receives cataphoresis electrocoating to limit surface oxidation. Inside, a stainless steel impeller works alongside bronze wear rings and a BQQE shaft seal. Physical net weight measures 60 kg.

Electrical power for the NB 40-125/127 model is supplied by a 415 V three-phase electric motor rated at 3 kW output power. Nominal operating current draw measures 10.3 Amps during full load operations. Operating liquid temperatures span from -25°C to 120°C under 16 bar working pressure. Suction inlet measures DN 65 with a DN 40 discharge port.

Motor protection on the NB 40-125/127 pump complies with IP55 enclosure standards to resist dust and moisture ingress, supported by Class F thermal insulation and internal PTC thermistors. The back-pull-out casing layout allows service personnel to remove the motor drive and rotor assembly without unbolting the pump volute from system suction and discharge piping headers.

Features

  • Mechanical shaft seal can be replaced without removing the impeller, system piping, pump volute casing or drive motor from the installation.
  • Housing, impeller and wear ring use dissimilar material pairings to prevent galling and ensure no sticking elements during extended standby periods.
  • High-efficiency motor selection is configured to match the specific power supply characteristics, pumping environment and liquid properties of each installation.
  • Back pull-out design allows complete rotating assembly removal including motor, coupling and impeller without disturbing pump housing or connected pipework.
  • EN733 and ISO2858 dimensional compliance ensures interchangeability with other standard end-suction pumps across commercial and industrial installations.
  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow750 L/Min
Max Head16.09 m
Power3 kW / 415v
Rated Current10.3 Amps
Suitable ForIndustrial Water Infrastructure
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size65 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Community heating substations select The Grundfos NB 40-125/127 for high-capacity tempered water movement through community headers. Heavy-duty shaft seals maintain sealed containment across demanding winter heating cycles, avoiding plant room leaks.

  • District Substations
  • Community Headers
  • District Heating Mains
  • Secondary Heating

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
Delivering steady fluid push across primary skids, what peak dynamic head is certified?

Delivering steady hydraulic pressure to headers, Grundfos NB 40-125/127 attains a maximum dynamic head of approximately 16.09 m.

Supplying volumetric water movement to primary headers, what peak flow rate is attained?

Supplying volumetric water movement to primary headers, NB 40-125/127 provides an operational volume of approximately 750 L/Min.

For primary plant distribution duty, what materials form the volute casing and dynamic runner?

The baseplate-mounted pressure chamber of NB-40-125-127 integrates heavy cast iron with a precision-cast bronze impeller.

Under full speed pumping conditions, how much electrical power and load current are drawn?

Operating across primary headers, NB 40 125 127 draws 10.3 Amps across a three-phase 415 V electrical supply to run its 3 kW motor.

Supplying hot water to primary headers, which liquid temperature boundaries and pressures apply?

Thermal capability certified for NB/40/125/127 encompasses fluid operating temperatures from -25°C to 120°C with pressure retention to 16 bar.