Max Flow
740 L/Min
Max Head
29.6 m
Power
5.5 kW / 415v
Ideal Use
Boiler Plant & Thermal Transfer

Product Overview

Driven by a 5.5 kW electric motor, the NB 40-160/158 end-suction centrifugal pump features an axial suction port (DN 65) and a radial discharge port (DN 40). Specified for commercial HVAC circulation, district heating installations, and industrial process water distribution, the pump mounts securely onto floor inertia bases in mechanical plant rooms.

Hydraulic wet-end output delivers a rated flow volume of 740 L/Min with a maximum operational head limit of 29.6 m. The EN-GJL-250 cast iron casing receives cataphoresis electrocoating to limit surface oxidation. Inside, a stainless steel impeller works alongside bronze wear rings and a BQQE shaft seal. Physical net weight measures 101 kg.

Electrical power for the NB 40-160/158 model is supplied by a 415 V three-phase electric motor rated at 5.5 kW output power. Nominal operating current draw measures 10.5 Amps during full load operations. Operating liquid temperatures span from -25°C to 120°C under 16 bar working pressure. Suction inlet measures DN 65 with a DN 40 discharge port.

Motor protection on the NB 40-160/158 pump complies with IP55 enclosure standards to resist dust and moisture ingress, supported by Class F thermal insulation and internal PTC thermistors. The back-pull-out casing layout allows service personnel to remove the motor drive and rotor assembly without unbolting the pump volute from system suction and discharge piping headers.

Features

  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.
  • O-ring seal between pump housing and cover eliminates leakage risk at the volute-to-cover joint under sustained operating pressures.
  • Optimised impeller and volute hydraulics deliver unimpeded liquid flow through the pump casing, reducing internal turbulence losses.
  • All stainless steel shaft construction provides improved corrosion resistance compared to carbon steel alternatives in wetted service areas.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow740 L/Min
Max Head29.6 m
Power5.5 kW / 415v
Rated Current10.5 Amps
Suitable ForBoiler Plant & Thermal Transfer
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size65 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Major central energy plants moving high-temperature water depend on The Grundfos NB 40-160/158 for robust volumetric displacement across district mains. Heavy-duty electric drive power delivers reliable hydraulic lift, overcoming severe elevation resistance across regional distribution lines.

  • Central Energy Plants
  • District Heating Mains
  • High-Temperature Water
  • Central Utilities

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
Operating in primary plant circulation, what liquid thermal limits and working pressure are certified?

Hydronic duty across fluid temperatures of -25°C to 120°C is supported by Grundfos NB 40-160/158 alongside maximum line pressures of 10 bar.

Operating across primary central manifolds, what peak dynamic lift is delivered on site?

The end-suction centrifugal wet end in NB 40-160/158 achieves a peak dynamic head rating of approximately 29.6 m.

Operating in primary plant circulation, what peak volumetric flow rate can this pump sustain?

The end-suction volute geometry of NB-40-160-158 sustains a maximum volumetric throughput of approximately 740 L/Min.

In heavy mechanical plant installations, what materials comprise the casing and rotating parts?

The heavy-duty wet end architecture of NB 40 160 158 features an EN-GJL-250 cast iron volute alongside a precision-cast bronze impeller.

To operate this heavy-duty induction drive, what motor kilowatts, line voltage, and amps are needed?

Delivering steady mechanical torque, NB/40/160/158 operates a 5.5 kW electric motor connected to a three-phase 415 V feed at 10.5 Amps.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed