Product Overview
Specified for commercial building services, process water loops, and district cooling infrastructure, the NB 40-160/172 end-suction centrifugal pump incorporates DN 65 suction and DN 40 discharge flanged ports. The end-suction volute design connects directly to suction line headers and concrete foundation bases.
At nominal operational speed, hydraulic output provides 807 L/Min flow throughput alongside a maximum head limit of 36.85 m. Structural construction incorporates an EN-GJL-250 cast iron body with cataphoresis surface finish. Internal components feature a stainless steel impeller and BQQE seal. Total net weight stands at 110 kg.
The NB 40-160/172 electric motor operates on a 415 V three-phase supply drawing 14.3 Amps rated current at 7.5 kW output power. Fluid handling parameters accommodate liquid temperatures between -25°C to 120°C up to 16 bar system pressure. Line connection uses opposite DN 65 inlet and DN 40 outlet flanged ports.
Enclosure protection on the NB 40-160/172 model meets IP55 standards while motor windings feature Class F insulation and PTC thermistor protection relays. Maintenance technicians can extract the drive unit using back-pull-out access without removing the cast iron volute casing from connected plant room piping manifolds.
Features
- Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
- PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.
- O-ring seal between pump housing and cover eliminates leakage risk at the volute-to-cover joint under sustained operating pressures.
- Optimised impeller and volute hydraulics deliver unimpeded liquid flow through the pump casing, reducing internal turbulence losses.
- All stainless steel shaft construction provides improved corrosion resistance compared to carbon steel alternatives in wetted service areas.
- Mechanical shaft seal can be replaced without removing the impeller, system piping, pump volute casing or drive motor from the installation.
- Housing, impeller and wear ring use dissimilar material pairings to prevent galling and ensure no sticking elements during extended standby periods.
IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 807 L/Min |
| Max Head | 36.85 m |
| Power | 7.5 kW / 415v |
| Rated Current | 14.3 Amps |
| Suitable For | Industrial Water Infrastructure |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 65 mm |
| Outlet Size | 40 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Engineered for baseplate inertia mounting, what maximum dynamic head does this end-suction pump develop?
In heavy municipal heating networks, Grundfos NB 40-160/172 delivers an operational dynamic head of approximately 36.85 m.
Across wide municipal transmission headers, what maximum volumetric throughput is delivered per minute?
In heavy municipal transmission mains, NB 40-160/172 maintains a maximum volumetric flow throughput of approximately 807 L/Min.
What specific cast iron metallurgy and closed runner alloy provide mechanical endurance in this casing?
Featuring an electrocoated EN-GJL-250 cast iron volute casing, NB-40-160-172 utilizes a durable stainless steel impeller to withstand heavy hydraulic wear.
What electrical input power, incoming supply voltage, and operational amperage run this heavy electric drive?
Powered by a heavy induction motor rated at 7.5 kW, NB 40 160 172 connects to a three-phase 415 V electrical feed and draws 14.3 Amps at full load.
What media operating temperature boundary and maximum system working pressure can this pump withstand?
Operating in primary municipal loops, NB/40/160/172 accommodates liquid temperatures from -25°C to 120°C and sustains pressures up to 10 bar.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us