Grundfos NB 50-160/136 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209300

Grundfos NB 50-160/136 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller

$5,474.43 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1162 L/Min
Max Head
20.75 m
Power
5.5 kW / 415v
Ideal Use
Industrial Water Infrastructure

Product Overview

Driven by a 5.5 kW electric motor, the NB 50-160/136 end-suction centrifugal pump features an axial suction port (DN 65) and a radial discharge port (DN 50). Specified for commercial HVAC circulation, district heating installations, and industrial process water distribution, the pump mounts securely onto floor inertia bases in mechanical plant rooms.

Hydraulic wet-end output delivers a rated flow volume of 1162 L/Min with a maximum operational head limit of 20.75 m. The EN-GJL-250 cast iron casing receives cataphoresis electrocoating to limit surface oxidation. Inside, a stainless steel impeller works alongside bronze wear rings and a BQQE shaft seal. Physical net weight measures 104 kg.

Electrical power for the NB 50-160/136 model is supplied by a 415 V three-phase electric motor rated at 5.5 kW output power. Nominal operating current draw measures 10.5 Amps during full load operations. Operating liquid temperatures span from -25°C to 120°C under 16 bar working pressure. Suction inlet measures DN 80 with a DN 50 discharge port.

Motor protection on the NB 50-160/136 pump complies with IP55 enclosure standards to resist dust and moisture ingress, supported by Class F thermal insulation and internal PTC thermistors. The back-pull-out casing layout allows service personnel to remove the motor drive and rotor assembly without unbolting the pump volute from system suction and discharge piping headers.

Features

  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.
  • O-ring seal between pump housing and cover eliminates leakage risk at the volute-to-cover joint under sustained operating pressures.
  • Optimised impeller and volute hydraulics deliver unimpeded liquid flow through the pump casing, reducing internal turbulence losses.
  • All stainless steel shaft construction provides improved corrosion resistance compared to carbon steel alternatives in wetted service areas.
  • Mechanical shaft seal can be replaced without removing the impeller, system piping, pump volute casing or drive motor from the installation.
  • Housing, impeller and wear ring use dissimilar material pairings to prevent galling and ensure no sticking elements during extended standby periods.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1162 L/Min
Max Head20.75 m
Power5.5 kW / 415v
Rated Current10.5 Amps
Suitable ForIndustrial Water Infrastructure
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size65 mm
Outlet Size50 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Primary heating loops in healthcare facilities select The Grundfos NB 50-160/136 for reliable baseplate-mounted water propulsion. Rigid baseplate construction dampens vibration transmission, maintaining low noise levels adjacent to sensitive patient environments.

  • Healthcare Facilities
  • Primary Heating Loops
  • Hospital Plant Rooms
  • Boiler Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
Under full-speed rotational forces, what structural metals resist mechanical fatigue on site?

Cataphoresis electrocoating protects the baseplate volute of Grundfos NB 50-160/136, which operates with a precision-cast bronze impeller.

For heavy-duty municipal operation, what incoming voltage, motor power, and full load amps are needed?

To drive the end-suction runner, NB 50-160/136 utilizes a 5.5 kW motor operating from a three-phase 415 V feed drawing 10.5 Amps.

In terms of fluid tolerance, what liquid temperature boundaries and system pressures are certified on site?

Thermal engineering on NB-50-160-136 provides dependable fluid circulation between -25°C to 120°C under line pressures up to 10 bar.

For high-elevation urban heating networks, how high can this heavy centrifugal unit elevate water?

Discharging circulating liquid into primary headers, NB 50 160 136 develops a dynamic head of approximately 20.75 m.

Through heavy floor-mounted distribution manifolds, what peak flow rate is achieved on site?

Through heavy-duty plant skids, NB/50/160/136 sustains an operational liquid circulation of approximately 1162 L/Min.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed