Grundfos NB 50-200/181 Cast Iron 11 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209309

Grundfos NB 50-200/181 Cast Iron 11 kW End Suction Centrifugal Pump with Closed Impeller

$7,710.95 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1184 L/Min
Max Head
38.94 m
Power
11 kW / 415v
Ideal Use
High-Capacity Plant Room Pumping

Product Overview

The NB 50-200/181 single-stage end-suction pump operates on a 415 V three-phase supply rated at 11 kW drive power. Built with an axial inlet port (DN 65) and top radial outlet port (DN 50), the unit connects into commercial hydronic heating networks, cooling tower water loops, and facility fluid transfer lines.

Under full duty load, the pump generates 1184 L/Min rated flow capacity and reaches a maximum head threshold of 38.94 m. The heavy volute housing uses electrocoated cast iron to resist internal corrosion. A stainless steel impeller rotor assembly with bronze wear rings drives fluid transfer. Net product weight equals 147 kg.

Drive power on the NB 50-200/181 pump comes from a 11 kW electric motor operating on a 415 V three-phase electrical connection. Full-load running current measures 21.5 Amps. The pump processes liquid media over temperatures from -25°C to 120°C under line pressures up to 16 bar. Pipe connections use DN 65 suction and DN 50 discharge flanges.

Built with an IP55 rated motor enclosure and Class F insulation, the NB 50-200/181 electric motor incorporates internal PTC thermistor sensors against overheating. Servicing is simplified by the back-pull-out structural layout, enabling complete rotor and drive removal without disconnecting suction or discharge pipe joints.

Features

  • EN733 and ISO2858 dimensional compliance ensures interchangeability with other standard end-suction pumps across commercial and industrial installations.
  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1184 L/Min
Max Head38.94 m
Power11 kW / 415v
Rated Current21.5 Amps
Suitable ForHigh-Capacity Plant Room Pumping
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size65 mm
Outlet Size50 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Boiler plant headers in institutional facilities utilize The Grundfos NB 50-200/181 for dependable vertical water propulsion. Sturdy casing construction resists mechanical piping distortion under severe thermal operating conditions, supporting dependable plant duty.

  • Boiler Plant Headers
  • Institutional Facilities
  • Building Risers
  • Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
Responding to peak winter heating demands, how much fluid volume can this heavy pump move?

Across floor-mounted distribution trunk lines, Grundfos NB 50-200/181 circulates an operational volume of approximately 1184 L/Min.

How does the material composition of this unit maintain hydraulic shape across prolonged duty cycles?

Internal pressure containment in NB 50-200/181 relies on an EN-GJL-250 cast iron casing paired with a precision-cast bronze impeller.

What electrical input specifications in kilowatts, voltage profile, and current govern this pump?

Under full mechanical load, NB-50-200-181 consumes 21.5 Amps from a three-phase 415 V line to power its 11 kW electric motor.

Across primary heating loops, what liquid temperatures and working pressures are supported by this unit?

Accommodating demanding temperature cycles from -25°C to 120°C, NB 50 200 181 maintains seal integrity under working pressures to 16 bar.

Overcoming massive friction head across transmission pipework, what peak discharge lift is achieved?

Displacing fluid across regional utility headers, NB/50/200/181 sustains a peak dynamic head of approximately 38.94 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us