Grundfos NB 65-125/125 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209326

Grundfos NB 65-125/125 Cast Iron 5.5 kW End Suction Centrifugal Pump with Closed Impeller

$5,325.76 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1658 L/Min
Max Head
14.85 m
Power
5.5 kW / 415v
Ideal Use
Cooling Tower Hydronic Systems

Product Overview

The NB 65-125/125 single-stage end-suction pump operates on a 415 V three-phase supply rated at 5.5 kW drive power. Built with an axial inlet port (DN 80) and top radial outlet port (DN 65), the unit connects into commercial hydronic heating networks, cooling tower water loops, and facility fluid transfer lines.

Under full duty load, the pump generates 1658 L/Min rated flow capacity and reaches a maximum head threshold of 14.85 m. The heavy volute housing uses electrocoated cast iron to resist internal corrosion. A stainless steel impeller rotor assembly with bronze wear rings drives fluid transfer. Net product weight equals 107 kg.

Drive power on the NB 65-125/125 pump comes from a 5.5 kW electric motor operating on a 415 V three-phase electrical connection. Full-load running current measures 10.5 Amps. The pump processes liquid media over temperatures from -25°C to 120°C under line pressures up to 16 bar. Pipe connections use DN 80 suction and DN 65 discharge flanges.

Built with an IP55 rated motor enclosure and Class F insulation, the NB 65-125/125 electric motor incorporates internal PTC thermistor sensors against overheating. Servicing is simplified by the back-pull-out structural layout, enabling complete rotor and drive removal without disconnecting suction or discharge pipe joints.

Features

  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1658 L/Min
Max Head14.85 m
Power5.5 kW / 415v
Rated Current10.5 Amps
Suitable ForCooling Tower Hydronic Systems
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size80 mm
Outlet Size65 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Educational campus heating manifolds incorporate The Grundfos NB 65-125/125 for high-flow low-resistance fluid circulation. Broad suction and discharge porting enables heavy volumetric throughput while keeping motor power consumption economical.

  • Educational Campuses
  • Primary Boiler Headers
  • Campus Facilities
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
In regional heating substations, how much vertical discharge head is sustained under peak duty?

Through rigid end-suction volute chambers, Grundfos NB 65-125/125 sustains a peak dynamic head rating of approximately 14.85 m.

Moving heavy hydronic throughput across headers, what peak flow capacity is sustained on site?

In commercial boiler facilities, NB 65-125/125 supplies an operational volumetric circulation of approximately 1658 L/Min.

How does the cast iron casing with cataphoresis electrocoating endure long plant service intervals?

Electrodeposition surface treatment protects the casing of NB-65-125-125, driving fluid via a precision-cast bronze impeller.

How much electrical power does this large drive require across incoming voltage and amperage?

Designed for non-stop pumping duty, NB 65 125 125 features a 5.5 kW drive operating on a three-phase 415 V line drawing 10.5 Amps.

Under fluctuating water temperatures, what minimum and maximum liquid limits are permitted on site?

Thermal tolerance certified for NB/65/125/125 safely encompasses process liquid temperatures from -25°C to 120°C at pressures to 10 bar.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed