Grundfos NB 65-200/177 Cast Iron 15 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209341

Grundfos NB 65-200/177 Cast Iron 15 kW End Suction Centrifugal Pump with Closed Impeller

$8,328.98 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1582 L/Min
Max Head
37.74 m
Power
15 kW / 415v
Ideal Use
Industrial Water Infrastructure

Product Overview

Driven by a 15 kW electric motor, the NB 65-200/177 end-suction centrifugal pump features an axial suction port (DN 80) and a radial discharge port (DN 65). Specified for commercial HVAC circulation, district heating installations, and industrial process water distribution, the pump mounts securely onto floor inertia bases in mechanical plant rooms.

Hydraulic wet-end output delivers a rated flow volume of 1582 L/Min with a maximum operational head limit of 37.74 m. The EN-GJL-250 cast iron casing receives cataphoresis electrocoating to limit surface oxidation. Inside, a stainless steel impeller works alongside bronze wear rings and a BQQE shaft seal. Physical net weight measures 156 kg.

Electrical power for the NB 65-200/177 model is supplied by a 415 V three-phase electric motor rated at 15 kW output power. Nominal operating current draw measures 29.1 Amps during full load operations. Operating liquid temperatures span from -25°C to 120°C under 16 bar working pressure. Suction inlet measures DN 100 with a DN 65 discharge port.

Motor protection on the NB 65-200/177 pump complies with IP55 enclosure standards to resist dust and moisture ingress, supported by Class F thermal insulation and internal PTC thermistors. The back-pull-out casing layout allows service personnel to remove the motor drive and rotor assembly without unbolting the pump volute from system suction and discharge piping headers.

Features

  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.
  • Ball bearing support arrangement accommodates both radial and axial thrust loads generated during continuous duty operation at rated speed.
  • PN16 flanged connection ratings on sizes up to and including DN 150 provide elevated working pressure capability beyond standard EN733 10 bar ratings.

IMPORTANT:Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1582 L/Min
Max Head37.74 m
Power15 kW / 415v
Rated Current29.1 Amps
Suitable ForIndustrial Water Infrastructure
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size80 mm
Outlet Size65 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Campus district heating networks depend on The Grundfos NB 65-200/177 for high-head fluid transport. The heavy motor delivers strong hydraulic thrust, overcoming severe pipeline friction across regional multi-building loops.

  • District Heating Mains
  • Campus Facilities
  • Transmission Networks
  • Central Utilities

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
How much electrical energy in kilowatts, line voltage, and amperage does this heavy unit draw?

Electrical feeds must provide a three-phase 415 V supply for Grundfos NB 65-200/177, whose 15 kW motor pulls 29.1 Amps at full capacity.

In heavy plant rooms, what maximum liquid temperature and operating line pressure are sustained by this pump?

Extreme thermal conditions across -25°C to 120°C are sustained by NB 65-200/177 within maximum line pressure limits of 10 bar.

For heavy transmission headers, what total vertical elevation column is sustained under load?

The robust spiral volute of NB-65-200-177 develops an operational dynamic lift rating of approximately 37.74 m.

Supplying bulk fluid movement to primary loops, what maximum volumetric throughput is achieved?

Across primary cooling skids, NB 65 200 177 sustains a maximum volumetric liquid volume of approximately 1582 L/Min.

Under demanding hydronic duty, which metals protect the casing from mechanical line distortion?

Resisting internal oxidation across process lines, NB/65/200/177 utilizes an electrocoated cast iron body with a precision-cast bronze impeller.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us