Max Flow
18600 L/Min
Max Head
30.8 m
Power
41 kW / 415v
Ideal Use
Wastewater Treatment

Product Overview

High-volume displacement in municipal wet wells is the primary function of the Grundfos S2.100.200.400.4.62L.S.285.G.N.D.513, which is intended for permanent submerged service. This cast iron pump manages untreated wastewater and sewage containing solids in centralized collection sumps. It ensures consistent hydraulic transfer in infrastructure environments with liquid temperatures from 0°C to +40°C.

A 41 kW 4-pole motor at 1464 rpm powers the unit, which achieves a maximum flow of 18600 L/min and a maximum head of 30.8 m. Drawing 82 Amps on a three-phase 415 V supply, stable motor operation is maintained during high-capacity transfer. This configuration provides reliable pumping performance for volume-intensive wastewater infrastructure.

Wastewater is transferred through a 2-channel cast iron impeller with a 287 mm diameter and a 100 mm free passage for handling sewage containing solids. The DN 200 outlet features DIN flange standards and a PN 10 rating to support high-volume transfer. This design focuses on high-capacity displacement while helping to reduce the risk of clogging in municipal grid systems.

Structural integrity is provided by an EN-GJL-250 cast iron pump housing and motor casing with double SIC/SIC-CARBON mechanical seals. Safety monitoring is managed by integrated moisture sensors and thermal switches to ensure motor safety in submerged conditions. The unit is supplied with a 15-metre H07RN-F power cable and is compatible with the Grundfos DN200 auto-coupling system (96641489).

FEATURES

  • 2-Channel cast iron impeller with a 287 mm diameter and 100 mm passage for handling solids.
  • EN-GJL-250 cast iron pump housing and motor casing for structural durability in permanent stations.
  • Double mechanical shaft seal with SIC primary seal and SIC-CARBON secondary barrier protection.
  • Integrated moisture sensors and thermal switches for proactive motor protection and monitoring.
  • IP68 enclosure suitable for installation depths up to 20 metres with a PN 10 rated DN200 outlet.
  • Supplied with a 15-metre H07RN-F power cable for reliable electrical connection in basins.
  • Suitable for high-volume transfer applications in municipal sewage and wastewater networks.
  • Compatible with the Grundfos DN200 auto-coupling system (96641489) for simplified maintenance access.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow18600 L/Min
Max Head30.8 m
Power41 kW / 415v
Rated Current82 Amps
Suitable ForWastewater Treatment
Body MaterialCast Iron
Liquid Temperature0°C to +40°C
Outlet Size200 mm
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

In municipal wet wells requiring high-volume displacement, The Grundfos S2.100.200.400.4.62L discharges raw sewage and effluent through wide distribution mains. The balanced dual passage design maintains steady flow velocity while preventing particulate settlement across large collection chambers.

  • Municipal Wet Wells
  • High-Capacity Sumps
  • Wastewater Treatment Works

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
In high-capacity municipal collection wet wells, what peak volumetric displacement is sustained per minute?

In high-capacity municipal collection wet wells, Grundfos S2.100.200.400.4.62L sustains a peak volumetric flow of 18600 L/Min.

Which metallic composition is chosen for the heavy volute casing and dual-channel fluid displacement parts?

Utilizing an EN-GJL-250 cast iron volute and a balanced cast iron two-channel rotating channel, S2.100.200.400.4.62L maintains structural integrity under heavy duty.

What motor power rating, electrical supply voltage, and steady running current operate this heavy submerged motor?

Operating on a three-phase 415 V electrical line, S2-100-200-400-4-62L relies on a heavy 41 kW motor with an operational current of 82 Amps.

What wastewater thermal range, casing pressure rating, and maximum submerged installation depth are approved?

In submerged municipal stations, S2 100 200 400 4 62L functions within fluid temperatures of 0°C to 40°C, sustaining internal working pressures up to PN 10 at depths up to 20 metres.

In municipal sewage lift stations, what peak dynamic lift pressure does this heavy submersible pump maintain?

In municipal sewage lift stations, S2/100/200/400/4/62L maintains an operational dynamic head reaching 30.8 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed