With flow capacity reaching 23400 L/min and maximum head of 18.1 m, the Grundfos S2.100.300.500.4.62E.C.289.G.N.D.513GPA submersible sewage pump is suited to wastewater, process water and unscreened raw sewage transfer where very high flow rates at low heads are required. The Variant C cooling jacket enables continuous submerged operation at depths up to 20 m.
A 50 kW motor (P2) at 1470 rpm from a 415 V three-phase supply draws 98 A with 89% efficiency at full load and 90% at 3/4 load. The 292 mm impeller delivers the specified performance, with DN300 outlet and DN100 inlet connections carrying a PN10 pressure rating for this configuration.
Hydraulic performance is provided by a 2-channel cast iron impeller with 100 mm free passage, with the impeller diameter and dual-channel configuration matched to the E lifting height class requirements. The impeller geometry determines the head and flow characteristics for this Range 62 model.
Cast iron construction with IP68 enclosure and Class F insulation provides submerged durability, with primary silicon carbide and secondary silicon carbide-carbon shaft seals preventing liquid ingress. Integrated moisture sensors are fitted as standard, and the 15 m H07RN-F AT cable supports Star/Delta starting.
FEATURES
- Range 62 Motor Design: The motor frame incorporates standardized external and internal dimensions, cooling system configuration, shaft seal arrangement and bearing specification common to all pumps in the Range 62 series.
- 2-Channel Cast Iron Impeller: The dual-channel impeller design provides stable hydraulic performance across the operating range while maintaining efficient solids handling capability for municipal wastewater applications.
- 100 mm Free Passage: The internal clearance through the impeller and volute allows solids and unscreened sewage particulates to pass without blocking the hydraulic flow path during operation.
- DN300 / DN100 Connection: The outlet connection is sized at DN300 with a PN10 pressure rating, while the inlet connection is DN100, matching the hydraulic design requirements of this configuration.
- Variant C Cooling Jacket: The integrated cooling jacket surrounds the motor stator to dissipate heat during continuous submerged operation, maintaining stable motor temperatures in wet well installations.
- IP68 Enclosure Protection: The motor housing is fully sealed against permanent submersion, with the IP68 rating confirming suitability for continuous operation at depths up to 20 m.
- Silicon Carbide Shaft Seals: The primary shaft seal uses silicon carbide faces while the secondary seal employs a silicon carbide-carbon combination, providing two-stage protection against liquid ingress into the motor compartment.
- Integrated Moisture Sensors: Sensors are fitted within the motor housing to detect the presence of moisture, providing early indication of potential seal degradation or liquid ingress during service.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 23400 L/Min |
| Max Head | 18.1 m |
| Power | 50 kW / 415v |
| Rated Current | 98 Amps |
| Suitable For | High Capacity Wastewater Systems |
| Body Material | Cast iron |
| Liquid Temperature | 0°C to +40°C |
| Inlet Size | 300 mm |
| Outlet Size | 300 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What peak flow rate and standardized flanged discharge diameter apply to this sewage pump?
Piping networks interface directly with the S2.100.300.500.4.62E.C.289 through a DN 300 (standard flanged connection), accommodating a peak delivery flow rate of approximately 23400 L/Min.
To process stringy wastewater and solids, what alloy construction and casing metallurgy are utilized?
Wastewater particulate management on the Grundfos S2.100.300.500.4.62E.C.289 relies on Cast iron housing and wetted components and a balanced channel impeller accommodating solids measuring up to 100 mm.
Under nominal utility power, what operating electrical voltage and motor kilowatt capacity are demanded?
Electrical motor specifications on the S2-100-300-500-4-62E-C-289 designate a power output of 50 kW operating across 415 V, 50 Hz, three-phase drawing 98 A.
Under demanding sump conditions, what installation depth and liquid temperature boundary are supported?
Structured for deep wet pit service, the S2 100 300 500 4 62E C 289 handles operational installation depths up to approximately 20 m in effluent up to 40°C.
What dynamic lift head can this large sewage unit develop upward across vertical lines?
Vertical elevation performance on the S2.100.300.500.4.62E.C.289.G.N.D.513GPA is evaluated at a peak dynamic head of approximately 18.1 m.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us