Grundfos S2.120.250.1000.6.70H.S.500 Ductile Iron 6-Pole Sewage Pump for Domestic Use with 2-Channel Impeller
SKU: 96810562

Grundfos S2.120.250.1000.6.70H.S.500 Ductile Iron 6-Pole Sewage Pump for Domestic Use with 2-Channel Impeller

$67,327.50 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
2 Year Warranty
Peace of Mind
Max Flow
28200 L/Min
Max Head
41.5 m
Power
100 kW / 415v
Ideal Use
Domestic Wastewater

Product Overview

Highlighting extended continuous circulation capacities, this pump is natively designed for handling wastewater, process water, unscreened raw sewage, municipal, domestic and industrial applications. The S2.120.250.1000.6.70H.S.500.G.N.D.513GPA unit is strictly suitable for submerged physical installation setups utilizing the active 96782483 auto coupling interface connection base to establish deep continuous fluid transfer capabilities.

Constructed from solid Ductile cast iron EN 1563 EN-GJS-500-7, the physical outer housing surrounds central dynamic components. The 2-channel impeller, measuring exactly 500 mm in overall diameter, effectively processes suspended physical solids up to 120 mm in size. The internal core motor casing is manufactured from Cast iron EN 1561 EN-GJL-250. The mechanical unit weighs 1300 kg and operates strictly in Newtonian liquids up to 40°C.

The 100 kW electrical motor works on a three-phase 415v continuous power supply, operating with a designated steady continuous current of 183 Amps. The heavy industrial unit achieves a maximum head of 41.5 meters and a maximum flow volume of 28200 L/Min running directly through a DN 250 mm discharge outlet. The continuous operating power input P1 is specified directly at 109 kW, running alongside an electrical starting current rated exactly at 1200 Amps.

System thermal safety is strictly provided by Class F internal motor insulation combined with a rated IP68 physical enclosure parameter. The extensive hardware fully supports continuous vertical physical installation depths reaching up to 20 meters. Primary SIC mechanical seals and secondary SIC-CARBON shaft seals precisely provide constant internal fluid containment. The operational architecture incorporates a 6-pole motor matched with a Y/D starting mechanism.

Features

  • Features lifting height class H standard dimension specification for operation
  • Integrates internal physical moisture sensors explicitly for continuous fluid system evaluation
  • Includes core hardware thermistors designed for active thermal response observations
  • Utilizes H07RN-F AT specification active power cable measuring precisely 15 meters
  • Operates actively with a continuous mechanical baseline speed of 984 revolutions per minute
  • Accommodates a standard maximum of 15 electrical motor starts per operational hour

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow28200 L/Min
Max Head41.5 m
Power100 kW / 415v
Rated Current183 Amps
Suitable ForDomestic Wastewater
Body MaterialDuctile Cast Iron
Liquid TemperatureMaximum 40°C
Outlet Size250 mm
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Circulating unscreened municipal wastewater across long-distance treatment headers, The Grundfos S2.120.250.1000.6.70H.S.500 delivers substantial head lift and steady volumetric displacement. Submerged utility sumps utilize this powerful configuration to prevent pipe sedimentation along extended outfalls.

  • Submerged Utility Sumps
  • Long-Distance Treatment Headers
  • Municipal Sewage Mains

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
What motor kilowatt rating, three phase supply voltage, and full-load running current apply to this heavy pump?

The electrical power plant of Grundfos S2.120.250.1000.6.70H.S.500 provides 100 kW from a three-phase 415 V feed, drawing a running current of 183 Amps.

What wastewater thermal boundaries, casing pressure ratings, and maximum submersion depth govern this transmission unit?

The operating boundaries of S2.120.250.1000.6.70H.S.500 accommodate sewer transmission temperatures from 0°C to 40°C alongside a PN 10 rating for submersion up to 20 metres.

Across long-distance sewage transmission headers, what maximum dynamic head does this heavy submersible unit reach?

Across long-distance sewage transmission headers, S2-120-250-1000-6-70H-S-500 reaches a maximum dynamic elevation of 41.5 m.

Across long-distance sewage transmission headers, what maximum fluid volume is displaced through outfall lines?

Across long-distance sewage transmission headers, S2 120 250 1000 6 70H S 500 maintains a peak fluid displacement capacity of 28200 L/Min.

Which grades of ductile iron constitute the heavy external housing and internal solids-handling channels?

The high-capacity hydraulic body of S2/120/250/1000/6/70H/S/500 is cast from EN-GJS-500-7 ductile iron, encasing a precision-balanced ductile iron two-channel assembly.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us