Grundfos S3.120.600.1000.6.70E.S.402 Ductile Iron 6-Pole Sewage Pump for Municipal Use with 3-Channel Impeller
SKU: 96810574

Grundfos S3.120.600.1000.6.70E.S.402 Ductile Iron 6-Pole Sewage Pump for Municipal Use with 3-Channel Impeller

$112,618.93 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
61200 L/Min
Max Head
11.3 m
Power
100 kW / 415v
Ideal Use
Municipal Sewage

Product Overview

Detailing internal fluid path stability, this submersible pump is exclusively structured for handling wastewater, process water, unscreened raw sewage, municipal, domestic and industrial applications. The S3.120.600.1000.6.70E.S.402.G.N.D.513GPA unit is definitively suitable for submerged liquid installation configurations natively utilizing the 96782486 auto coupling structural interface connection layout.

Constructed from Ductile cast iron EN 1563 EN-GJS-500-7, the structural external housing encapsulates active internal mechanical components. The 3-channel impeller, measuring 403 mm in continuous diameter, processes solid material up to 120 mm in physical size. The core internal motor housing is manufactured from Cast iron EN 1561 EN-GJL-250. The physical unit weighs 2020 kg and operates strictly in Newtonian liquids up to 40°C.

The 100 kW motor operates on a three-phase 415v power supply maintaining a steady rated continuous current of 183 Amps. The physical hardware achieves a maximum head of 11.3 meters and a maximum continuous flow of 61200 L/Min passing through a DN 600 mm discharge outlet. The continuous operational electrical power input P1 is specified at 109 kW, running with an initial starting current rated exactly at 1200 Amps.

Motor protection is formally provided by Class F internal insulation combined with an IP68 designated physical enclosure rating. The heavy hardware structurally supports continuous vertical installation depths extending up to 20 meters. Primary SIC mechanical seals and secondary SIC-CARBON shaft seals rigidly provide internal fluid containment boundaries. The electrical system utilizes a standard 6-pole motor configuration combined with a Y/D method.

Features

  • Features lifting height class E dimension standard for continuous fluid output
  • Integrates specialized internal moisture sensors for fluid intrusion evaluation
  • Includes functional core thermistors engineered for active internal temperature tracking
  • Utilizes H07RN-F AT specification power cable measuring exactly 15 meters
  • Operates structurally with a continuous mechanical speed of 984 revolutions per minute
  • Accommodates exactly 15 standard electrical motor starts per operational hour

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow61200 L/Min
Max Head11.3 m
Power100 kW / 415v
Rated Current183 Amps
Suitable ForMunicipal Sewage
Body MaterialDuctile Cast Iron
Liquid TemperatureMaximum 40°C
Outlet Size600 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Municipal utilities managing primary sewage collection mains depend on the Grundfos S3.120.600.1000.6.70E.S.402 to move heavy wastewater through regional wet wells. It maintains consistent hydraulic velocity to prevent particulate settling across wide piping manifolds.

  • Municipal Mains
  • Sewage Treatment
  • Lift Stations
  • Wet Wells

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
What maximum dynamic head and vertical lift elevation can this submersible wastewater pump reach?

Delivering strong vertical hydraulic lift, the S3.120.600.1000.6.70E.S.402 achieves a maximum dynamic head rating of approximately 11.3 m.

Under maximum fluid displacement, what peak delivery flow volume and outlet connection does this pump sustain?

Discharging through its DN 600 (standard flanged connection), the Grundfos S3.120.600.1000.6.70E.S.402 sustains a maximum delivery flow volume of approximately 61200 L/Min.

Regarding solid waste handling, what alloy material, casing metallurgy, and spherical passage are featured?

Manufactured with Ductile Cast Iron housing and wetted components, the S3-120-600-1000-6-70E-S-402 incorporates a robust 3-channel impeller capable of safely passing spherical solid debris up to 120 mm.

What electrical motor power, supply voltage, and rated operating current feed this pump?

Driven by an industrial electric motor rated at 100 kW, the S3 120 600 1000 6 70E S 402 operates on 415 V, 50 Hz, three-phase drawing a rated current of 183 A.

What maximum installation depth limit, permissible liquid temperature, and thermal boundary apply?

Submerged in wastewater collection basins, the S3.120.600.1000.6.70E.S.402.G.N.D.513GPA supports installation depths up to approximately 20 m with fluid temperatures up to 40°C.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us