Roll over image to zoom
SKU: 98346582
Grundfos TP 32-90/2 Cast Iron 0.37kW Three Phase Inline Centrifugal Pump with Composite Impeller
Australia-Wide
(08) 9240 2992
Official Grundfos
Peace of Mind
Product Overview
Handling operating liquid temperatures from -25°C to 120°C, the TP 32-90/2 inline centrifugal pump is rated for maximum working pressures up to 16 bar. The system incorporates a maintenance-free mechanical shaft seal to contain circulating media across heating and cooling networks without leaking.
Constructed with an EN-GJL-250 cast iron casing, the housing body features cataphoresis electrocoating surface treatment for internal corrosion protection. The internal hydraulic assembly contains a precision composite impeller fitted with bronze wear rings and a maintenance-free mechanical shaft seal. Net product weight measures 10.1 kg for fixed mounting placement in mechanical plant rooms.
The motor operates on a 415 V three-phase supply rated at 1.74 Amps nominal operating current. Operating liquid temperatures span from -25°C to 120°C under maximum working pressures up to 16 bar. In-line opposite port geometry with DN 32 flanged connections enables mounting directly into straight pipework lines or onto foundation bases.
Motor protection features an IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistors. Top-pull-out structural design enables removal of the motor head and impeller assembly without dismantling the pump housing from connected system pipework lines during scheduled servicing routines.
Features
- In-line structural design with opposite suction and discharge ports for direct pipework line mounting.
- EN-GJL-250 cast iron pump casing with protective cataphoresis electrocoating surface treatment.
- Internal hydraulic rotor assembly incorporating a precision manufactured composite impeller.
- Rated hydraulic output capacity achieving 9 m maximum head and 146 L/Min flow rate.
- Standardized DN 32 flanged connection ports for commercial HVAC and heating installation.
- IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistor motor protection.
- Top-pull-out mechanical layout allowing service access without removing volute casing from pipework lines.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 146 L/Min |
| Max Head | 9 m |
| Power | 0.37 kW / 415v |
| Rated Current | 1.74 Amps |
| Suitable For | Boiler circulation |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 32 mm |
| Outlet Size | 32 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What maximum flow discharge rate does this three phase centrifugal pump deliver?
High-efficiency three-phase pumping by the Grundfos TP 32-90/2 delivers a maximum flow rate of approximately 146 L/Min.
What casing metallurgy and impeller material are featured in this three phase centrifugal pump?
Manufactured with a rugged Cast Iron housing and a premium Composite Impeller, the TP 32-90/2 delivers exceptional structural strength.
What motor kilowatt rating, supply voltage and running current govern this three phase pump?
Supplied for three-phase electrical skids, the TP-32-90-2 features a motor rating of 0.37 kW / 415v with a full-load current of 1.74 Amps.
What liquid temperature limits and operating pressure ratings govern this three phase centrifugal pump?
Designed for demanding plant room circuits, the TP 32 90 2 circulates fluids across an extensive temperature range of -25°C to 120°C.
What maximum dynamic head elevation can this three phase inline centrifugal pump achieve?
Driven by three-phase electric power, the TP/32/90/2 develops a maximum dynamic head rating of approximately 9 m.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us