Power delivery in the TP 50-180/2 inline pump is provided by a 415 V three-phase electric motor rated at 0.75 kW output power. Rated operating current measures 3.30 Amps, driving the internal stainless steel impeller to produce a maximum head limit of 18 m under full operational load.
Constructed with an EN-GJL-250 cast iron casing, the housing body features cataphoresis electrocoating surface treatment for internal corrosion protection. The internal hydraulic assembly contains a precision stainless steel impeller fitted with bronze wear rings and a maintenance-free mechanical shaft seal. Net product weight measures 28.1 kg for fixed mounting placement in mechanical plant rooms.
The motor operates on a 415 V three-phase supply rated at 3.30 Amps nominal operating current. Operating liquid temperatures span from -25°C to 120°C under maximum working pressures up to 16 bar. In-line opposite port geometry with DN 50 flanged connections enables mounting directly into straight pipework lines or onto foundation bases.
Motor protection features an IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistors. Top-pull-out structural design enables removal of the motor head and impeller assembly without dismantling the pump housing from connected system pipework lines during scheduled servicing routines.
Features
- In-line structural design with opposite suction and discharge ports for direct pipework line mounting.
- EN-GJL-250 cast iron pump casing with protective cataphoresis electrocoating surface treatment.
- Internal hydraulic rotor assembly incorporating a precision manufactured stainless steel impeller.
- Rated hydraulic output capacity achieving 18 m maximum head and 305 L/Min flow rate.
- Standardized DN 50 flanged connection ports for commercial HVAC and heating installation.
- IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistor motor protection.
- Top-pull-out mechanical layout allowing service access without removing volute casing from pipework lines.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 305 L/Min |
| Max Head | 18 m |
| Power | 0.75 kW / 415v |
| Rated Current | 3.3 Amps |
| Suitable For | Commercial heating |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
How many liters per minute of liquid delivery can this heavy centrifugal pump sustain?
Hydraulic velocity sustained by the Grundfos TP 50-180/2 provides a maximum flow delivery of approximately 305 L/Min.
What durable casing metallurgy and rotating components are engineered into this pump?
Designed for rigorous duty, the TP 50-180/2 pairs a thick-walled Cast Iron body with a precision-cast Stainless Steel Impeller.
What motor kilowatt capacity, supply voltage and full load current are certified for this pump?
Configured for plant room electrical supplies, the TP-50-180-2 consumes 0.75 kW / 415v while drawing a running current of 3.3 Amps.
What maximum liquid temperature and internal system pressure are certified for this centrifugal pump?
Fluid media temperatures spanning -25°C to 120°C are safely circulated by the TP 50 180 2 under high system pressure.
What peak dynamic head can this three phase centrifugal pump sustain across building headers?
Vertical hydraulic force produced by the TP/50/180/2 establishes a maximum dynamic head of approximately 18 m.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us