Roll over image to zoom
SKU: 96108760
Grundfos TP 80-240/2 Cast Iron 5.5kW Three Phase Inline Centrifugal Pump with Bronze Impeller
Australia-Wide
(08) 9240 2992
Official Grundfos
Peace of Mind
Product Overview
Motor winding protection in the TP 80-240/2 inline pump is provided by PTC thermistors connected to control relays alongside Class F insulation. The IP55 rated enclosure housing resists environmental dust and water ingress in plant room locations.
Constructed with an EN-GJL-250 cast iron casing, the housing body features cataphoresis electrocoating surface treatment for internal corrosion protection. The internal hydraulic assembly contains a precision bronze impeller fitted with bronze wear rings and a maintenance-free mechanical shaft seal. Net product weight measures 90.9 kg for fixed mounting placement in mechanical plant rooms.
The motor operates on a 415 V three-phase supply rated at 11 Amps nominal operating current. Operating liquid temperatures span from -25°C to 120°C under maximum working pressures up to 16 bar. In-line opposite port geometry with DN 80 flanged connections enables mounting directly into straight pipework lines or onto foundation bases.
Motor protection features an IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistors. Top-pull-out structural design enables removal of the motor head and impeller assembly without dismantling the pump housing from connected system pipework lines during scheduled servicing routines.
Features
- EN-GJL-250 cast iron pump casing with protective cataphoresis electrocoating surface treatment.
- Rated hydraulic output capacity achieving 24 m maximum head and 1131 L/Min flow rate.
- In-line structural design with opposite suction and discharge ports for direct pipework line mounting.
- Standardized DN 80 flanged connection ports for commercial HVAC and heating installation.
- Internal hydraulic rotor assembly incorporating a precision manufactured bronze impeller.
- IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistor motor protection.
- Top-pull-out mechanical layout allowing service access without removing volute casing from pipework lines.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 1131 L/Min |
| Max Head | 24 m |
| Power | 5.5 kW / 415v |
| Rated Current | 11 Amps |
| Suitable For | Campus heating |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 80 mm |
| Outlet Size | 80 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
In high-rise distribution risers, what dynamic discharge head does this flanged circulator sustain?
In primary heating headers, Grundfos TP 80-240/2 delivers a maximum dynamic head of approximately 24 m.
Across wide-bore distribution manifolds, what maximum volumetric throughput is delivered per minute?
Displacing fluid across wide-bore distribution manifolds, TP 80-240/2 delivers an operational throughput of approximately 1131 L/Min.
What specific metallurgy and rotating components provide mechanical endurance in this casing?
Constructed with an electrocoated EN-GJL-250 cast iron casing, TP-80-240-2 incorporates a precision-cast bronze impeller for hydraulic durability.
What electrical input power, incoming supply voltage, and operational amperage run this machine?
Powered by a 5.5 kW electric motor, TP 80 240 2 connects to a three-phase 415 V power line and draws 11.0 Amps at full load.
What media operating temperature boundary and maximum system pressure can this unit withstand?
Operating in primary closed loops, TP/80/240/2 accommodates liquid temperatures from -25°C to 120°C and withstands pressures up to 16 bar.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us











