Grundfos TPE3 100-230 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Cast Iron Impeller
SKU: 93338859

Grundfos TPE3 100-230 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Cast Iron Impeller

$16,369.93 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1960 L/Min
Max Head
14.7 m
Power
5.5 kW / 415v
Ideal Use
Heating & Cooling Systems

Product Overview

Driven by an integrated 5.5 kW drive motor, the TPE3 100-230 single-stage inline centrifugal pump provides continuous liquid circulation across commercial HVAC networks, chilled water loops, and facility hydronic circuits. Its in-line structural layout incorporates matching DN 100 inlet and outlet flanges to streamline plant room pipework installation.

At full duty speed, hydraulic throughput reaches 1960 L/Min with a maximum head threshold of 14.7 m. Casing construction uses robust electrocoated cast iron (EN-GJL-250) to resist internal surface oxidation. Fluid transfer is driven by a Cast iron impeller paired with an industry-standard BQQE shaft seal. Physical net weight is 124 kg.

Power requirements specify a 3 x 380-500 V Three-phase electrical supply rated for 5.5 kW output, with full-load running current measuring 10.5 Amps. Operating liquid temperatures span from -25°C to 120°C across active HVAC circuits. Standardized DN 100 suction and DN 100 discharge flanged ports facilitate direct line insertion.

The drive motor is housed within an IP55 rated enclosure featuring Class F winding insulation to protect against thermal stress. Built-in frequency control with an integrated PI controller enables automatic variable speed adjustment according to active hydronic load. Maintenance operations utilize a service-friendly top-pull-out design, allowing complete rotor disassembly while the cast iron housing remains fixed in the pipe run.

Features

  • Maintenance-free BQQE mechanical shaft seal prevents fluid leakage and maintains seal integrity under elevated working pressures.
  • IP55 motor enclosure protection guards internal electrical components against ambient dust accumulation and water splash ingress.
  • Class F thermal motor insulation permits continuous operation under elevated fluid temperatures ranging from -25°C to 120°C.
  • Equal suction and discharge port diameters enable straightforward inline installation without requiring custom pipe reducer spools.
  • Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
  • Top-pull-out structural layout enables complete drive head and impeller extraction without disconnecting the pump casing from system piping.
  • High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1960 L/Min
Max Head14.7 m
Power5.5 kW / 415v
Rated Current10.5 Amps
Suitable ForHeating & Cooling Systems
Body MaterialEN-GJL-250 Cast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size100 mm
Outlet Size100 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download

Secondary hydronic headers in convention centers select The Grundfos TPE3 100-230 for balanced, variable volumetric displacement. Direct in-line port configuration eliminates the need for bulky floor baseplates, saving space in multi-use utility areas.

  • Secondary Hydronic Headers
  • Convention Centers
  • Utility Areas
  • Mechanical Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
During systematic hydronic duty, what fluid temperature ratings and pressure boundaries apply?

Handling broad climate control demands, Grundfos TPE3 100-230 accommodates circulating liquid media across -25°C to 120°C at pressures to 16 bar.

Regulating circulating momentum dynamically, what maximum delivery head does this unit provide?

Adapting motor output to prevent excess loop pressure, TPE3 100-230 achieves a peak dynamic head of approximately 14.7 m.

Modulating liquid displacement across multi-story risers, how many liters per minute are circulated?

The electronically managed runner of TPE3-100-230 maintains an operational liquid delivery of approximately 1960 L/Min.

How do the cast iron housing and specialized impeller resist erosive fluid circulation?

The flanged wet end of TPE3 100 230 integrates an EN-GJL-250 cast iron pressure volute with an aerodynamically balanced cast iron impeller (EN-GJL-200).

Under full electrical frequency, what kilowatt rating, incoming supply, and current are drawn?

Electrical feeds must provide a three-phase 415 V supply for TPE3/100/230, whose 5.5 kW motor pulls 10.5 Amps at peak capacity.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed