Grundfos TPE3 100-260 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Cast Iron Impeller
SKU: 93338863

Grundfos TPE3 100-260 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Cast Iron Impeller

$18,458.88 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
2122 L/Min
Max Head
18.4 m
Power
7.5 kW / 415v
Ideal Use
Heating & Cooling Systems

Product Overview

Operating on a 7.5 kW motor drive, the TPE3 100-260 single-stage inline pump handles fluid transfer across commercial building services, cooling tower circuits, and hydronic heating headers. Standardized DN 100 suction and discharge flanges permit inline line mounting, eliminating complex foundation coupling procedures.

Liquid handling performance provides a nominal flow rate of 2122 L/Min against a maximum head limit of 18.4 m. The cast iron volute body (EN-GJL-250) offers corrosion barrier protection for hydronic loops. The internal rotor houses a Cast iron impeller assembly supported by a BQQE shaft seal. Equipment net weight stands at 130 kg.

Engineered for Three-phase electrical systems (3 x 380-500 V), the 7.5 kW motor draws 14.1 Amps full-load current. Operating liquid temperatures cover a wide -25°C to 120°C span up to 16 bar system working pressure. Opposite DN 100 inlet and DN 100 discharge flanges provide standard pipe header compatibility.

Enclosure protection meets IP55 weatherization standards, supported by Class F motor insulation against high ambient temperatures. An onboard frequency converter with closed-loop PI control allows real-time variable speed tuning. The top-pull-out power head geometry permits technicians to perform seal or impeller maintenance while keeping the volute casing installed in system pipework headers.

Features

  • Equal suction and discharge port diameters enable straightforward inline installation without requiring custom pipe reducer spools.
  • Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
  • Top-pull-out structural layout enables complete drive head and impeller extraction without disconnecting the pump casing from system piping.
  • High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.
  • EN-GJL-250 cast iron volute housing provides robust pressure containment up to 16 bar in demanding hydronic circulation loops.
  • Corrosion-resistant Cast iron impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
  • Standardized DN 100 flanged connections comply with EN 1092-2 for seamless drop-in integration into commercial pipe headers.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow2122 L/Min
Max Head18.4 m
Power7.5 kW / 415v
Rated Current14.1 Amps
Suitable ForHeating & Cooling Systems
Body MaterialEN-GJL-250 Cast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size100 mm
Outlet Size100 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download

District heating secondary substations install The Grundfos TPE3 100-260 to circulate hot water smoothly through extensive facility networks. Real-time energy reporting built into the drive module assists facility staff in verifying ongoing system efficiency gains.

  • District Substations
  • District Heating Mains
  • Secondary Heating
  • Central Utilities

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Under closed-loop speed feedback, what total dynamic elevation height is developed across headers?

Through closed-loop differential tracking, Grundfos TPE3 100-260 maintains a maximum dynamic elevation of approximately 18.4 m.

With integrated frequency regulation, what maximum volumetric fluid volume does this unit provide?

Under closed-loop speed modulation, TPE3 100-260 circulates a maximum volumetric throughput of approximately 2122 L/Min.

Which high-integrity materials are incorporated into the pressure casing of this unit?

To maintain structural shape across fluctuating loads, TPE3-100-260 pairs a heavy cast iron shell with an aerodynamically balanced cast iron impeller (EN-GJL-200).

How much electrical power does this smart drive consume across rated voltage and running amps?

The speed controlled electric drive of TPE3 100 260 delivers 7.5 kW of rotational output on a three-phase 415 V connection at 14.1 Amps.

Across primary circulating loops, which thermal operating limits and pressure ratings govern this unit?

Thermal capability certified for TPE3/100/260 encompasses fluid operating temperatures from -25°C to 120°C with pressure retention to 16 bar.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us