Operating on a 5.5 kW motor drive, the TPE3 125-160 single-stage inline pump handles fluid transfer across commercial building services, cooling tower circuits, and hydronic heating headers. Standardized DN 125 suction and discharge flanges permit inline line mounting, eliminating complex foundation coupling procedures.
Liquid handling performance provides a nominal flow rate of 2703 L/Min against a maximum head limit of 10.7 m. The cast iron volute body (EN-GJL-250) offers corrosion barrier protection for hydronic loops. The internal rotor houses a Cast iron impeller assembly supported by a BQQE shaft seal. Equipment net weight stands at 142 kg.
Engineered for Three-phase electrical systems (3 x 380-500 V), the 5.5 kW motor draws 10.5 Amps full-load current. Operating liquid temperatures cover a wide -25°C to 120°C span up to 16 bar system working pressure. Opposite DN 125 inlet and DN 125 discharge flanges provide standard pipe header compatibility.
Enclosure protection meets IP55 weatherization standards, supported by Class F motor insulation against high ambient temperatures. An onboard frequency converter with closed-loop PI control allows real-time variable speed tuning. The top-pull-out power head geometry permits technicians to perform seal or impeller maintenance while keeping the volute casing installed in system pipework headers.
Features
- Corrosion-resistant Cast iron impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
- Standardized DN 125 flanged connections comply with EN 1092-2 for seamless drop-in integration into commercial pipe headers.
- Maintenance-free BQQE mechanical shaft seal prevents fluid leakage and maintains seal integrity under elevated working pressures.
- IP55 motor enclosure protection guards internal electrical components against ambient dust accumulation and water splash ingress.
- Class F thermal motor insulation permits continuous operation under elevated fluid temperatures ranging from -25°C to 120°C.
- Equal suction and discharge port diameters enable straightforward inline installation without requiring custom pipe reducer spools.
- Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 2703 L/Min |
| Max Head | 10.7 m |
| Power | 5.5 kW / 415v |
| Rated Current | 10.5 Amps |
| Suitable For | Heating & Cooling Systems |
| Body Material | EN-GJL-250 Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 125 mm |
| Outlet Size | 125 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
In massive primary cooling headers, what peak dynamic elevation does this large variable unit sustain?
In large-scale cooling plant mains, Grundfos TPE3 125-160 delivers an operational dynamic lift of approximately 10.7 m.
In high-capacity cooling plants, what maximum volumetric throughput is displaced per minute?
In massive plant distribution networks, TPE3 125-160 maintains a maximum volumetric flow throughput of approximately 2703 L/Min.
Which metallurgy is selected for the heavy volute casing and dynamic runner of this large unit?
Constructed with an EN-GJL-250 cast iron volute housing, TPE3-125-160 features an aerodynamically balanced cast iron impeller (EN-GJL-200) for structural resilience.
What electrical input power, three phase voltage, and operational amperage run this large smart drive?
Equipped with an integrated 5.5 kW motor, TPE3 125 160 connects to a three-phase 415 V power line and draws 10.5 Amps at full load.
In massive central cooling loops, what fluid temperature boundaries and line pressure apply?
Operating in primary cooling networks, TPE3/125/160 accommodates media temperatures from -25°C to 120°C and sustains pressures up to 16 bar.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us