Roll over image to zoom
SKU: 93338899
Grundfos TPE3 125-290 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Cast Iron Impeller
Australia-Wide
(08) 9240 2992
Official Grundfos
Peace of Mind
Product Overview
Engineered for high-efficiency fluid circulation in hydronic building systems, the TPE3 125-290 is a single-stage, close-coupled in-line centrifugal pump driven by a 11 kW electric motor. Featuring equal suction and discharge porting (DN 125), this unit connects directly into vertical or horizontal header pipe runs across HVAC plant rooms, district heating loops, and commercial water circuits.
Under nominal duty conditions, the wet-end hydraulic assembly generates a rated flow capacity of 2902 L/Min alongside a maximum operational head limit of 19.57 m. The volute housing is constructed from EN-GJL-250 cast iron to ensure high structural pressure containment up to 16 bar. Inside, a precision-balanced Cast iron impeller works in tandem with a BQQE mechanical shaft seal. Net equipment weight measures 174 kg.
Electrical power for the TPE3 125-290 pump is supplied by a 3 x 380-500 V Three-phase electrical connection drawing 20.3 Amps under full load. The unit accommodates operating fluid media temperatures ranging from -25°C to 120°C under continuous line pressure ratings up to 16 bar. Pipework mounting is supported by opposite DN 125 inlet and DN 125 outlet flanged connections.
Motor protection complies with IP55 enclosure standards to guard internal windings against dust and moisture ingress, backed by Class F thermal insulation. An integrated frequency converter and PI controller provide continuously variable speed regulation to optimize energy consumption against system demand. The top-pull-out structural layout permits maintenance technicians to withdraw the motor drive and impeller assembly without unbolting the pump volute from connected system pipework flanges.
Features
- Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
- Top-pull-out structural layout enables complete drive head and impeller extraction without disconnecting the pump casing from system piping.
- High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.
- EN-GJL-250 cast iron volute housing provides robust pressure containment up to 16 bar in demanding hydronic circulation loops.
- Corrosion-resistant Cast iron impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
- Standardized DN 125 flanged connections comply with EN 1092-2 for seamless drop-in integration into commercial pipe headers.
- Maintenance-free BQQE mechanical shaft seal prevents fluid leakage and maintains seal integrity under elevated working pressures.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 2902 L/Min |
| Max Head | 19.57 m |
| Power | 11 kW / 415v |
| Rated Current | 20.3 Amps |
| Suitable For | Heating & Cooling Systems |
| Body Material | EN-GJL-250 Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 125 mm |
| Outlet Size | 125 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What specific housing alloys and rotating parts provide mechanical containment in this pump?
To resist hydrodynamic wear across plant headers, Grundfos TPE3 125-290 is engineered with a cast iron casing and an aerodynamically balanced cast iron impeller (EN-GJL-200).
Which electrical parameters in motor wattage, incoming supply, and full load amps govern this unit?
Operating on a three-phase 415 V connection, TPE3 125-290 features a smart 11 kW motor with an operational current draw of 20.3 Amps.
Through heavy-duty plant headers, what maximum media temperature and operating pressure apply?
Circulating media temperatures from -25°C to 120°C are accommodated by TPE3-125-290 with pressure retention to 16 bar.
To support expansive central energy manifolds, what dynamic discharge lift is delivered on site?
To support extensive multi-building cooling networks, TPE3 125 290 provides a peak dynamic elevation of approximately 19.57 m.
Supplying tremendous liquid volume to facility headers, how many liters per minute are circulated?
Supplying heavy circulating liquid to primary headers, TPE3/125/290 delivers an operational throughput of approximately 2902 L/Min.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us











